background image

8527-0544-2M Rev G 

 APS Enterprise Scale 

23

PARTS IDENTIFICATION, CONT. 

(APS250 ONLY) 

 

ITEM

 

PART NO.

 

QTY

DESCRIPTION

 

1 1960-B465-08 2 

SPACER 

FOR 

EB-XXX-XXXX 

3 6013-0077 4 

HEX 

NUT 

6013-0295 

NUT #10-32 HEX Z/P 

6021-0950 

SCW HEX-HEAD.. MACHINE-SCW 10-32X1.50 Z/P 

10 

6021-1108 

SCW FILLISTER. MACHINE-SCW 10-32X.375 

12 

6540-1123 

LEVELLER SCREW, 3/8-16 X 1 1/4”, BLACK 

13 

6560-1072 

A/R  ADHESIVE, LOCTITE 49 

16 

6690-0001 

BULLSEYE BUBBLE LEVEL 

17 

8527-0524-1A 

LOAD CELL ASSY, 100KG 

18 

8527-0525-08 

BASE PLATE, 250 

19 8527-0526-08 1 

COVER, 

18X18 

20 8527-0534-08 1 

TOP 

PLATE, 

250 

22 8527-C505-08 1 

PCB 

COVER 

 
A/R = AS REQUIRED 

Содержание APS10

Страница 1: ... ENTERPRISE SCALE Setup and Operation Manual CARDINAL SCALE MFG CO 8527 0544 2M Rev G PO BOX 151 WEBB CITY MO 64870 Printed in USA 03 15 PH 417 673 4631 FAX 417 673 5001 www detectoscale com Technical Support Ph 866 254 8261 techsupport cardet com ...

Страница 2: ...8527 0544 2M Rev G APS Enterprise Scale II ...

Страница 3: ...D CONFIGURATION Page 10 To Enter Setup Page 10 type Scale Type Page 10 Uns Motion Range Page 11 Filter Adjustable Digital Filtering Page 11 Calib Calibration Page 11 Port1 Serial Port 1 Page 12 Port2 Serial Port 2 Page 12 Port3 Serial Port 3 Page 13 USB USB Port Page 13 HirES High Resolution Weight Mode Page 14 btdis Button Disable Page 14 ERROR AND STATUS DISPLAYS Page 15 CARE AND CLEANING Page 1...

Страница 4: ... pictorial content in any manner is prohibited No patent liability is assumed with respect to the use of the information contained herein DISCLAIMER While every precaution has been taken in the preparation of this manual the Seller assumes no responsibility for errors or omissions Neither is any liability assumed for damages resulting from use of the information contained herein All instructions a...

Страница 5: ...4 in 31 cm x 36 cm 150 lb 0 05 lb 3000 TSP 100kg 60 kg 0 02 kg 3000 APS250 18 in x 18 in 46 cm x 46 cm 250 lb 0 1 lb 2500 TSP 100kg 113 kg 0 05 kg 2500 Power Requirements 100 to 240 VAC 50 60Hz 12 VDC 1A wall plug in UL CSA listed AC power adapter Cardinal part number 6800 1045 Operating Environment Temperature Range 14º to 104º F 10º to 40º C Display Five digit seven segment 0 875 inch 22 mm high...

Страница 6: ...readings Insure that the indicator has good clean AC power and is properly grounded In areas subject to lightning strikes additional protection to minimize lightning damage such as surge suppressors should be installed Environmental Conditions The APS Enterprise scale has been designed to operate under the following environmental conditions Indoor use only Ambient temperature range of 14 to 104 F ...

Страница 7: ... prevent possible adverse effects on the scale Examples of available alternatives include isolation transformers power regulators uninterruptible power supplies or simple line filters Transient Suppression The following recommendations will help to reduce transients Always use shielded cables to connect signal wires to the weight scale Do not run signal cables from the scale alongside or parallel ...

Страница 8: ...ctrical Power section of this manual for more instruction The scale is now ready for use Level Adjustment Place the scale in the chosen location and remove the stainless steel platform The platform can be removed by lifting upward on it removing it from the weighbridge Locate the small level indicator on the scale base to the right of the display and check to make certain that the scale is level N...

Страница 9: ...erial and shipping carton should be retained for possible examination by the shipping company 2 Remove the four leveling feet from the hardware pack and install in each corner of scale base as shown NOTE Leveling feet must be in place to operate the scale 3 To mount the display on the scale base use the two included mounting screws in the hardware pack 4 Insert the screws through the two holes in ...

Страница 10: ... stainless steel platform The platform can be removed by lifting upward on it removing it from the weighbridge Locate the small level indicator on the scale base to the right of the display and check to make certain that the scale is level NOT LEVEL LEVEL Bubble is not Bubble is within circle within circle If the level indicator does not show a level indication the mounting feet should be adjusted...

Страница 11: ... POS SERIAL PORT 3 NOTE The included serial data cable uses an RJ11 phone type connector scale base to a DB9 connector OPOS compatible serial device Plug the RJ11 connector of the included 4 serial data cable into the scale base where marked and then plug the other end into an available serial port on the POS device USB Cable Installation USB To use the USB interface obtain an industry standard Ty...

Страница 12: ...8527 0544 2M Rev G APS Enterprise Scale 8 INSTALLATION CONT Serial Data Cable 8527 0545 0A Included 4 Serial Data Cable 8527 0545 0A Wiring Diagram Serial Data Cable 8527 0545 0A 4 Feet ...

Страница 13: ...o the alternate units of measurement For example with pounds displayed pressing this key will change the weighting units to kilograms ANNUNCIATORS The annunciators are turned on to indicate that the display is in the mode corresponding to the annunciator label or that the status indicated by the label is active OZ This annunciator is turned on to indicate the weight displayed is in ounces lb This ...

Страница 14: ...he scale base 2 With the scale ON use a 1 8 or 3 mm Hex Key Wrench or other small tool and press the Calibration Switch 3 The display will change to show type Type Scale Type This will determine the capacity interval decimal and converted units if applicable Press the UNITS key to show current setting If value displayed is acceptable press the UNITS key again to save it Otherwise press the ZERO ke...

Страница 15: ...e calibration routine for the scale With display showing CALib press the UNITS key The display will change to show current setting no If scale has been previously calibrated and you wish to skip calibration and proceed to PORT1 press the UNITS key again and internal calibration factor will be retained To begin calibration press the ZERO key to select yes and then press the UNITS key After pressing...

Страница 16: ... change the behavior of the scale When the scale settles on any positive weight above zero the display will lock on that weight until the scale returns to zero PORt2 RS 232 Serial Port 2 This is the second serial port output format selection It is identical to PORT1 The serial port parameters for this port are fixed at 9600 baud 8 data bits 1 stop bit and No parity Press the UNITS key to show curr...

Страница 17: ...SICS output format LPL Lone Peak Labeling UPS UPS WorldShip output format IMPORTANT Selecting LPL Lone Peak Labeling for the port output format will change the behavior of the scale When the scale settles on any positive weight above zero the display will lock on that weight until the scale returns to zero Usb USB Port The USB port output format selections are similar to the serial port settings W...

Страница 18: ... mode no Units will be displayed and the scale is not Legal For Trade To exit the High Resolution Mode press and hold the ZERO ON OFF key to turn the scale off and then press the ZERO ON OFF to the scale back on btdis Button Disable This setting allows the keypad buttons to be disabled for use by the operator during normal operation During normal operation when the operator presses a disabled butt...

Страница 19: ...and void the warranty Always remove power before cleaning Do not use wire brushes abrasives or cleaning tools such as steel pads and scrapers which will scratch the surface Instead use soft cloths or plastic scouring pads for cleaning When possible use treated water Hard water can leave behind deposits Soft water is much gentler on the stainless steel and painted surfaces Avoid the use of acetone ...

Страница 20: ...Parts Department The part numbers are 6021 0605 SCW FILLISTER MACHINE SCW 06 32X 375 6024 0126 WASHER FLAT 6021 1108 SCW FILLISTER MACHINE SCW 10 32X 375 To install a lead and wire security seal follow the steps provided below 1 Remove the Calibration Switch Access screw and replace it with the drilled 10 32 screw Make certain it is securely tighten before proceeding 2 Remove the PCB Cover screw a...

Страница 21: ...ods The bracket can be attached to the wall using the appropriate hardware for the type of wall construction The remote display can be removed from the bracket and mounted on the wall using the included Velcro strips Using the remote display post it can be mounted to a table bench or in a retail environment the check stand ...

Страница 22: ...8527 0544 2M Rev G APS Enterprise Scale 18 PARTS IDENTIFICATION ALL MODEL EXCEPT APS250 ...

Страница 23: ... 8527 0521 0A 1 LOAD CELL ASSY 15KG APS10 APS20 18 8527 0521 1A 1 LOAD CELL ASSY 15KG APS30 19 8527 0522 0A 1 LOAD CELL ASSY 30KG APS70 20 8527 0523 08 1 BASE PLATE 150 21 8527 0524 0A 1 LOAD CELL ASSY 100KG APS150 22 8527 0527 08 1 BASE PLATE 70 23 8527 0528 08 1 COVER 12X14 24 8527 0529 08 1 TOP PLATE 8 10 12 25 8527 0530 08 1 TOP PLATE 160 15 20 26 8527 0531 08 1 TOP PLATE 30 27 8527 0532 08 1 ...

Страница 24: ...21 1108 2 SCW FILLISTER MACHINE SCW 10 32X 375 9 6021 1706 4 SCW FLAT HEAD CAP SCREW 25 20X 625 12 6650 0087 1 LABEL MADE IN USA WITH FLAG 1 X 1 35 8527 D510 0A 1 DISPLAY SUB ASSY 10 36 8527 D510 1A 1 DISPLAY SUB ASSY 160 37 8527 D510 2A 1 DISPLAY SUB ASSY 15 38 8527 D510 3A 1 DISPLAY SUB ASSY 30 40 8527 D510 5A 1 DISPLAY SUB ASSY 70 41 8527 D510 6A 1 DISPLAY SUB ASSY 150 42 8527 D510 9A 1 DISPLAY...

Страница 25: ...EM PART NO QTY DESCRIPTION 4 6021 0623 4 SCW PAN HEAD MACHINE SCW 06 32X 750 7 6021 1069 2 SCW CUP POINT SET SCREW 10 32X 25 NYLON PATCH 9 6021 1706 4 SCW FLAT HEAD CAP SCREW 25 20X 625 13 6680 0004 4 WASHER LOCK INT TOOTH 6 TYPE A Z PL 29 8527 C500 0A 1 ANALOG PCB 45 593R1007 2 FACTORY SET LABEL ...

Страница 26: ...8527 0544 2M Rev G APS Enterprise Scale 22 PARTS IDENTIFICATION CONT APS250 ONLY ...

Страница 27: ... 6021 0950 4 SCW HEX HEAD MACHINE SCW 10 32X1 50 Z P 10 6021 1108 2 SCW FILLISTER MACHINE SCW 10 32X 375 12 6540 1123 4 LEVELLER SCREW 3 8 16 X 1 1 4 BLACK 13 6560 1072 A R ADHESIVE LOCTITE 49 16 6690 0001 1 BULLSEYE BUBBLE LEVEL 17 8527 0524 1A 1 LOAD CELL ASSY 100KG 18 8527 0525 08 1 BASE PLATE 250 19 8527 0526 08 1 COVER 18X18 20 8527 0534 08 1 TOP PLATE 250 22 8527 C505 08 1 PCB COVER A R AS R...

Страница 28: ...1 0625 3 SCW FLAT HEAD MACHINE SCW 06 32X 375 7 6021 0659 4 SCW FLAT HEAD MACHINE SCW 06 32X1 00 9 6021 1069 1 SCW CUP POINT SET SCREW 10 32X 25 NYLON PATCH 10 6021 1108 2 SCW FILLISTER MACHINE SCW 10 32X 375 11 6021 1706 4 SCW FLAT HEAD CAP SCREW 25 20X 625 14 6650 0087 1 LABEL MADE IN USA WITH FLAG 1 X 1 23 8527 D510 7A 1 DISPLAY SUB ASSY 250 ...

Страница 29: ...5 PARTS IDENTIFICATION CONT APS250 ONLY ITEM PART NO QTY DESCRIPTION 5 6013 0315 4 NUT 6 32 HEX SMALL PATTERN Z P 11 6021 1706 4 SCW FLAT HEAD CAP SCREW 25 20X 625 15 6680 0004 4 WASHER LOCK INT TOOTH 6 TYPE A Z PL 21 8527 C500 0A 1 ANALOG PCB ...

Страница 30: ...15 08 1 APS KEYPAD 4 8527 C502 0A 1 PCB ASSY APS10 DISPLAY 5 8527 C502 1A 1 PCB ASSY APS15 160 DISPLAY 6 8527 C502 2A 1 PCB ASSY APS30 70 150 DISPLAY 7 8527 C502 3A 1 PCB ASSY APS250 DISPLAY 8 8527 C502 4A 1 PCB ASSY APSRD DISPLAY 9 8527 D506 08 1 ENCLOSURE FRONT 10 8527 D507 08 1 ENCLOSURE BACK 11 8527 D508 08 1 ENCLOSURE MOUNT DISPLAY EXTENSION CABLE ITEM PART NO QTY DESCRIPTION 6600 2007 1 CABL...

Страница 31: ...ipping charges prepaid A return authorization number must be obtained for all returns and marked on the outside of all returned packages Detecto accepts no responsibility for items lost or damaged in transit Conditions Which Void Limited Warranty This warranty shall not apply to equipment which A Has been tampered with defaced mishandled or has had repairs and modifications not authorized by Detect...

Страница 32: ...8527 0544 2M Rev G APS Enterprise Scale 28 ...

Отзывы: