8527-0544-2M Rev G
APS Enterprise Scale
11
SETUP AND CONFIGURATION, CONT.
UnS
(Motion Range)
This is the motion range of the scale, or the number of divisions that the scale weight can
change without setting the motion indicator.
Press the
UNITS
key to show current setting. If value displayed is acceptable, press the
UNITS
key again to save it. Otherwise, press the
ZERO
key to step through selections for
a new value and then press the
UNITS
key to save it.
Allowable values are 0 through 9.
FILtr
(Adjustable Digital Filtering)
This is the adjustable digital weight filtering that is applied to the weight in order to help filter
out vibrations or other noise that might make the weight unstable.
Press the
UNITS
key to show current setting. If value displayed is acceptable, press the
UNITS
key again to save it. Otherwise, press the
ZERO
key to step through selections for
a new value and then press the
UNITS
key to save it.
Allowable values are Off, 1, 2 or 3.
OFF
= No weight filtering
1
= Minimal weight filtering
2
= Moderate weight filtering
3
= Maximum weight filtering
CALIb
(Calibration)
This is the calibration routine for the scale.
With display showing
CALib
, press the
UNITS
key. The display will change to show
current setting
no
. If scale has been previously calibrated and you wish to skip calibration
and proceed to
PORT1
, press the
UNITS
key again and internal calibration factor will be
retained.
To begin calibration, press the
ZERO
key to select yes and then press the
UNITS
key.
After pressing the
UNITS
key, the display will change to
LOAd
.
1.
With
“LOAd
displayed, press the
UNITS
key. The display will change to show the
currently selected scale type’s capacity.
NOTE:
For convenience, you can press the
ZERO
key and change this to half of capacity.
2.
Once the test load weight is selected, placed the test load weight on the scale platform
and then press the
UNITS
key.
3.
Starting at the right and proceeding left, a series of dashes will appear on the display
and then starting at the left and proceeding right disappear. Next, the display will
change to the
UnLOd
prompt.
4.
Remove all weight from the scale platform and then press the
UNITS
key.
5.
Starting at the right and proceeding left, a series of dashes will appear on the display
and then starting at the left and proceeding right disappear. Next, the display will
change to the
PORT1
prompt. Calibration is complete. Proceed to
PORT1
.