8535-M074-O1 Rev C
6745 Baby Scale Operation
14
SETUP AND CALIBRATION, CONT.
Battery Type
With the display showing
niCAd=
press the
key to show current setting. If the value
displayed is acceptable, press the
key again to save it. Otherwise use the
UNITS
key to
select the new setting and then press the
key to save it.
NOTE:
This setting may be
revised without having to enter the calibration mode. Allowable values are:
0
Alkaline batteries - battery charging is DISABLED
1
NiCad or NiMH batteries - battery charging is ENABLED
2
Battery charging is ENABLED and FORCED ON. This selection
forces battery charging for NiCad or NiMH batteries that are
discharged.
NOTE:
After 15 hours of charging, the indicator will
automatically change the
niCAd=
setting back to a 1.
IMPORTANT: Selecting 1 or 2, enables battery charging. DO NOT select 1 or 2,
when using alkaline batteries.
Threshold
NOTE:
This prompt will only be displayed if you selected
USA =
1 (Domestic).
The display will change to show
tHrSh=
, the threshold lock value. This value is the weight in
ounces that the load on the scale must rise above for the Weight Lock feature to function.
Press the
key to show the current setting. If the value displayed is acceptable, press
the
key again to save it. Otherwise, use the
UNITS
and
ZERO
keys to enter a new
value and then press the
key to save it. Allowable values are: 0 through 99. Note, that a
setting of 0 will disable the threshold lock.
Power Up Zero
With the display showing
PUO=
press the
key to show current setting. If the value
displayed is acceptable, press the
key again to save it. Otherwise use the
UNITS
key to
select the new setting and then press the
key to save it.
NOTE:
This setting may be
revised without having to enter the calibration mode.
0
Power Up Zero is DISABLED
1
Power Up Zero is ENABLED. The weight display will be reset to
zero automatically when the scale is turned on.
Automatic Shutoff
The Automatic Shutoff feature will automatically turn the scale off after a predetermined period
of inactivity to prolong battery life. To turn the scale back on you must press the
ON
key.
With the display showing
ASH=
, press the
key to show the current setting. If the value
displayed is acceptable, press the
key again to save it. Otherwise, use the
UNITS
key
to select the number of minutes (
time approximate
) of inactivity before turning the scale off and
then press the
key to save it.
NOTE:
This setting may be revised without having to
enter the calibration mode. Allowable values are 0 through 9. Note that 0 disables the
Automatic Shutoff feature.
Содержание 6745
Страница 2: ...8535 M074 O1 Rev C 6745 Baby Scale Operation 2 I ...
Страница 22: ...8535 M074 O1 Rev C 6745 Baby Scale Operation 18 PART IDENTIFICATION ...
Страница 23: ...8535 M074 O1 Rev C 6745 Baby Scale Operation 19 PART IDENTIFICATION CONT ...
Страница 25: ...8535 M074 O1 Rev C 6745 Baby Scale Operation 21 PART IDENTIFICATION CONT ...
Страница 26: ...8535 M074 O1 Rev C 6745 Baby Scale Operation 22 PART IDENTIFICATION CONT ...
Страница 28: ...8535 M074 O1 Rev C 6745 Baby Scale Operation 24 ...