8200-M628-O1 Rev A
212G/212GX Installation & Technical
Page 27
SETUP AND CALIBRATION, CONT.
CLtAr=
(Clear Tare)
The Clear Tare feature allows the indicator to clear the Stored Tare weight when the Net
weight goes below a value greater than 1/2 the stored tare weight or goes below zero (a
negative net weight after display of a positive net weight). With this feature enabled, the
operator must re-set the tare after completion of a transaction when the load (container plus
item) is removed from the scale.
Press the
ENTER
key to show the current value. If the setting displayed is acceptable, press
the
ENTER
key again to save it. Otherwise, using the numeric keys,
0/NO
or
1/YES
, enter the
new setting and then press the
ENTER
key to save it.
CLtAr= YES
CLtAr= NO
Automatically clears Stored Tare
when Net weight goes below zero
Stored Tare is not cleared when
Net weight goes below zero
The following is a typical example of the Clear Tare feature in use
.
1. Place container on scale, then press
TARE
key (with diamond “T” symbol).
2. Load container with item to be weighed and perform normal weighing operation.
3. Remove load (item
AND
container) from scale.
4. Scale weight returns to below zero (weight of container) and is then reset to zero.
5. Operator is required to repeat step 1 before next weighing operation.
id=
(ID Prompt)
The
id=
(ID=) prompt enables an ID prompt before printing a ticket.
With the display showing
id=,
press the
ENTER
key to show the current value. If the setting
displayed is acceptable, press the
ENTER
key again to save it. Otherwise, using the numeric
keys,
0/NO
or
1/YES
, enter the new setting and then press the
ENTER
key to save it.
id= YES
id= NO
id=
will be displayed when
key is
pressed and printed on the ticket.
Normal print operation (no ID prompt)
will occur.
If you selected
id= 1
(Yes, ID Prompt), an additional prompt, "
a clr="
will be displayed.
If you selected
id= 0
(No ID Prompt) proceed to
A-d
(
A-d?)
Analog to Digital Filtering.
A cLr=
(Auto Clear ID)
The
a clr=
(Auto Clear ID) prompt determines whether the ID is automatically cleared after
printing the ticket. Note that it is only displayed when
id= YES
is selected.
With the display showing
a clr=,
press the
ENTER
key to show the current value. If the setting
displayed is acceptable, press the
ENTER
key again to save it. Otherwise, using the numeric
keys,
0/NO
or
1/YES
, enter the new setting and then press the
ENTER
key to save it.
A clr= YES
a clr= NO
Automatically clears the ID after the
ticket has printed.
ID is not cleared when ticket prints
and can be used for next transaction.
Содержание 212G
Страница 2: ...8200 M628 O1 Rev A 212G 212GX Installation Technical Page 2 ...
Страница 10: ...8200 M628 O1 Rev A 212G 212GX Installation Technical Page 6 INSTALLATION CONT Figure No 2 ...
Страница 16: ...8200 M628 O1 Rev A 212G 212GX Installation Technical Page 12 INSTALLATION CONT Main PCB Figure No 9 ...
Страница 27: ...8200 M628 O1 Rev A 212G 212GX Installation Technical Page 23 Lamp test on power up ...
Страница 52: ...8200 M628 O1 Rev A 212G 212GX Installation Technical Page 48 ...