8
• These instructions are aimed at professionally qualified "
installers of electrical equipment
" and must respect
the local standards and regulations in force. All materials used must be approved and must suit the environment
in which the installation is situated.
• All maintenance operations must be carried out by professionally qualified technicians. Before carrying out any
cleaning or maintenance operations make sure the power is disconnected at the mains.
• This appliance must be used exclusively for the purpose for which it has been made. "i.e.
for the command and
control of automatic installations with a 230 Vac power supply
".
Any non authorised modifications are to be considered improper dangerous and the complete responsibility of the
installer.
• A correct earth connection is fundamental in order to guarantee the electrical safety of the machine.
• Periodically check the condition of the power cable: If it shows any sign of wear or damage have it replaced by
the manufacturer or an authorised after sales service technician.
TECHNICAL SPECIFICATIONS
Power supply
Vac
230
Frequency
Hz
50-60
Overall power consumption
W
650
Nominal current input
A
2,8
Motors
Nr.
1
Maximum motor power consumption
W
600
Operating temperature
°C
-20…+55
Inputs
Powers supply binding posts
230 Vac
50-60 Hz
Earth binding post
Antenna binding post
Opening button input contact NO
Closing button input contact NO
Blocking button input NC
Anemometer signal input
Inverting photocells contact NC
Safety edge contact NC
Analogical safety edge input (
8.2 k
Ω
)
Outputs
Power output for 1 motor
600 W
Output powering external devices
24 Vac 7 W
Work time
Maximum programmable time
s
180
Pause time
Minimum programmable time
s
1
Maximum programmable time
s
60
IMPORTANT REMARKS
IMPORTANT REMARKS
IMPORTANT REMARKS
TO REDUCE THE RISK OF SEVERE INJURY OR DEATH READ THE FOLLOWING REMARKS CARE-
FULLY BEFORE PROCEEDING WITH THE INSTALLATION. PAY PARTICULAR ATTENTION TO ALL
THE PARAGRAPHS MARKED WITH THE SYMBOL
. NOT READING THESE IMPORTANT INSTRUC-
TIONS COULD COMPROMISE THE CORRECT WORKING ORDER OF THE SYSTEM.