10
- fasten the base
5
to the wall using the supplied screws and rawlplugs
6
;
- wire up the receiver
7
following the electrical drawing shown in figure 4;
- seal the wires and the rubber gasket
4
with a layer of silicon in order to guarantee a protection grade
of IP55;
- hook on the cover
8
, rotate it downwards
9
and connect it to the base;
- insert the cover holding screw
10
and fasten down.
Installation CDRX12 using an optional cable clamp (fig. 3)
• According to the installation requirements work out the wall mounting points;
- run the cable holding pipe
C
to the point at which you intend to affix the receiver (the 4-wire cable must
not exceed a diameter of Ø5 mm);
- using the template located inside the packing, trace the wall fastening points according to the CDRX12
dimensions shown in figure 1;
- remove the cover blocking screw
1a
, rotate the cover upwards
1b
and separate it from the base
1c
;
- using Ø 5 mm bit drill the holes in the marked positions
2
;
- fasten the base
3
to the wall using the supplied screws and rawlplugs
4
;
- using a Philips screwdriver
5
knock out the hole
6
located inside the cover;
- insert the cable clamp
7
and fasten down using the supplied nut
8
;
- pass the cable (max Ø5 mm) through the cable clamp
9
- carry out the electrical connections
10
following the diagram as shown in figure 4;
- pull the cable slightly downwards
11
;
- hook on the cover
12
, rotate it downwards
13
and connect it to the base;
- tighten the plastic nut
14
and apply a layer of silicon around the cable in order to guarantee a protection
grade of IP55.