Dip-Switch S3
Function mode settings
1
2
3
4
Mode
Description
ON ON OFF OFF
1
Low power use
: communications mode using different radio channels to
avoid interference -
channel 1
for security devices with firmware
V3.0
or later.
ON ON ON OFF
2
Low power use
: communications mode using different radio channels to
avoid interference -
channel 2
for security devices with firmware
V3.0
or later.
ON ON OFF ON
3
Low power use
: communications mode using different radio channels to
avoid interference -
channel 3
for security devices with firmware
V3.0
or later.
OFF OFF OFF OFF
4
Broadcast
:
The stationary unit checks the status of the transceiver interface
every 30 seconds. If a reply is not received from one or more safety devices
the system will set their statuses to ‘alarm’.
OFF OFF ON OFF
5
Broadcast
:
Same as mode 4 but it is reserved for systems made up of
security devices fitted with firmware
V2.0
or later.
ON OFF OFF OFF
6
Controlled loads
:
The stationary unit checks the status of the security
devices when asked to by the ECU. Only for photoelectric cell security devices.
ON OFF ON OFF
7
Controlled loads
:
Same as mode 6 but also compatible with the safety edge
security devices.
ON OFF OFF ON
8
Controlled loads
:
Same as mode 7 but the interface is powered by the controlled
load output on the ECU. This mode also supports battery powered operation.
OFF ON OFF OFF
9
Warning lights
: The stationary unit will check the security device status each
time the warning light output on the ECU is actived.