![Cardin Elettronica BL1924ASW Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/cardin-elettronica/bl1924asw/bl1924asw_manual_2556072019.webp)
19
Terminal board connections
7
CMN
common for all inputs and outputs.
8
ELS
electric lock output (fed continuously)
12 Vdc
-
15 W
.
9-10
LC-CH2
Potential free contact for the activation of the courtesy light (separate
power supply
Vmax=30 Vac/dc: Imax=1A
) or the second radio channel.
3ELECTIONISCARRIEDOUTUSINGJUMPER
J5
11
CMN
common for all inputs and outputs.
12
LP
24 Vdc
25 W
output for warning lights
intermittent activation (50%),
12,5 W
continuous activation.
13
LS
24 Vdc
3 W
output for an indicator light.
14
CMN
common for all inputs and outputs.
15
30 Vdc
controlled output, powering external loads
(1)
.
16
CMN
common for all inputs and outputs.
17
30 Vdc
output, powering external loads
(1)
.
18
TA
(NO contact) opening button input.
19
TC
(NO contact) closing button input.
20
TAL
(NO contact) limited opening button input.
21
TD
(NO contact) dynamic button input.
22
CMN
common for all inputs and outputs.
23
TB
(NC contact) stop button input (The opening of this contact interrupts the
cycle until a new movement command is given).
24
CSP
(NC contact) safety edge input. Opening this contact will provoke a travel
direction inversion during the closing stage and during the opening stage
(2)
.
25
FTCS
(NC contact) The opening of this contact will block all movement, until
the obstruction has been removed and the pause time has elapsed, due to
the safety device cutting in, the door will then continue moving in the closing
direction (only with automatic reclosing enabled).
26
FTCI
(NC contact) safety and control devices in input (photocells invert the
travel direction when an obstruction is detected). Opening this contact will
provoke a travel direction inversion during closure due to the cutting in of the
safety device.
27
EMRG2
(NO) emergency manoeuvre input 2.
28
EMRG1
(NO) emergency manoeuvre input 1.
29
CMN
common for the emergency buttons.
30
Inner conductor for radio receiver antenna (if an external antenna is fitted use
a coaxial type cable
RG58
with an impedance of
50
7
).
31
Outer conductor for radio receiver antenna.
Note
(1)
The total of the 2 external device outputs must not exceed
10 W.
Note
(2)
*UMPER
J6
IDENTIlESTHETYPEOFSAFETYEDGECONNECTEDTOBINDINGPOST
- in position
1
the safety edge with NC contact is selected;
- in position
2
the safety edge with
8.2 k
7
contact is selected;
If you bridge the
CSP
INPUTMOVEJUMPER
J6
TOPOSITION
1
(NC).
ALL UNUSED NC CONTACTS MUST BE JUMPED
and consequently the security
device test must also be deactivated (
FTCI
,
FTCS
$IPAND$IP
OFF
If you want to activate the
FTCI, FTCS
test both the transmission and receiver parts
OFTHESECURITYDEVICESMUSTBECONNECTEDTOTHEBINDINGPOSTMARKED
CTRL 30
Vdc
)FTHETESTISACTIVETHEREWILLBEASECONDDELAYBETWEENTHECOMMAND
transmission and movement of the gate/s.
Switch on the power and make sure that the indicator LEDs are in the following
condition.
- L1
Power on
ON
- L2
Battery charging
OFF
(3)
- L3
Wrong battery connection
OFF
(4)
- L4
Transmitter code programming indicator
OFF
- L5
)NDICATORFORTHEBLOCKINGBUTTON
TB
ON
(5)
- L6
)NDICATORFORTHEINVERTINGPHOTOELECTRICCELLS
FTCI
ON
(5)
- L7
)NDICATORFORTHESTOPPHOTOELECTRICCELLS
FTCS
ON
(5)
- L8
)NDICATORFORTHESAFETYEDGE
CSP"
ON
(5)
- L9
)NDICATORFORTHEOPENINGBUTTON
TA
OFF
- L10
)NDICATORFORTHEOPENINGBUTTON
TC
OFF
- L11
)NDICATORFORTHELIMITEDOPENINGBUTTON
TAL
OFF
- L12
)NDICATORFORTHESEQUENTIALCOMMAND
TD/CH1
OFF
Note
(3)
4HIS,%$IS
ON
WHENTHEBATTERYISCHARGING
Note
(4)
)FTHIS,%$IS
ON
INVERTTHEBATTERYPOWERCABLESIMMEDIATELY
Note
(5)
Check that the activation of the safety devices switches the corresponding
LEDs off.
If the
green power on LED "L1" doesn't light up
check the condition of the fuses
and the power cable connection at the transformer primary.
If
one or more of the safety LEDs do not light up
check the contacts of the
relative security devices and check that the unused safety device contacts have
been bridged.
B1
3IGNALBUZZER
via radio
MODE
CSER
Serial connection (only for diagnostics)
D1
Six-segment LED display
DS1
Selection dip-switch
F1
10A
blade
fuse
(6)
(motor power protection)
F2
10A
blade
fuse
(6)
(motor protection during battery operation)
F3
4A
blade fuse
(6)
(
24V
circuit protection)
F4
4A
blade fuse
(6)
(
24V
circuit protection during battery operation)
F5
4A
blade
fuse
(6)
(electric lock protection)
J1
Battery connection
J2
Transformer secondary protection
J3
Enable transmitter memorisation via radio
J4
Radio channel selection
J5
Binding posts 9, 10 selection (courtesy light/CH2 via radio)
J6
Safety edge selection
CSP
NC/
8.2 k
7
MM
Transmitter code memory module
P1
Programming button (
PROG
)
P2
Transmitter code memorization button (
MEMO
)
P3
Transmitter code cancellation button (
DEL
)
R1
Radio frequency module,
433 MHz
for
S449
transmitters
Note
(6)
:
These are
automotive
type blade fuses (max. voltage
58 V
)
CTRL 30Vdc
CMN
CMN
FTCI (N.C)
TD (N.O)
CMN
TC (N.O)
T
A
L (N.O)
TB (N.C)
LP
LS
OUT 30Vdc
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
LC/CH2
L2
L3
4A
4A
CSER
F5
29
28
27
CMN
EMRG 2
EMRG 1
COLORE
COLOUR CODE COLORATION
CABLAGGI
CODE
DES
CÂBLAGES
Bl Blu
Blue
Bleu
Gr Verde
Green
Vert
Gy Grigio
Grey
Gris
Yw Giallo
Yellow
Jaune
KABELFARBEN
COLORACIÓN
CABLEADOS
Bl Blau
Azul
Gr Grün
Verde
Gy Grau
Gris
Yw Gelb
A
m
arillo
Collega
m
ento
m
otori/encoder a 4 fili
Connecting
m
otor/4-wire encoder
Branche
m
ent
m
oteur/encodeur à 4 fils
Anschluss der Motor/Encoder
m
it 4 Drähten
Conexionado
m
otores/encoder de 4 conductores
7
8
3
4
5
6
1
2
3
4
5
6
1
2
Yw
Gy
Gr
Bl
ENCODER 1
Yw
Gy
Gr
Bl
ENCODER 2
M1
M2
CMN
ELS 12V
CMN
T
A
(N.O)
FTCS (N.C)
P1
F1
10
10
4A
4A
F3
F2
10
10
F4
4A
4A
J2
L1
J1
B1
CS 1283
DC 0406
30
31
J4
J3
R1
L10
L9
L7
L6
L11
L8
L5
1 2
3
P3
P2
L4
1 2 3 4 5 6 7 8 91
0
ON
DS1
TD
RA
PLP
LP
LS
FTCI
TFTI
TFTS
SAP
ELS
J5
Pos.1 Pos.2
1 2
3
1 2
3
J6
Pos.1 Pos.2
1 2
3
CSP (N.C)
L12
MM
D1
Содержание BL1924ASW
Страница 49: ...49 NOTES ...
Страница 50: ...50 NOTES ...