Part number 3E1100 R16 

 

July 2010 

 

Make the connections from the Prox Mifare Series (Teardrop) reader to either 
the Cardax FT Controller 3000-4R or 3000 as shown: 

Cardax FT Controller 3000-4R or 3000

PA

Group

PB1 and PA1... to... PB2 and PA2 (3000-4R)

           PB4 and PA4 (3000)

4         3          2         1

2         1

PB

Prox Mifare

Reader 1

Prox Mifare

Reader 2

 

Note:  

Within each group, you cannot mix Cardax IV readers with Wiegand 

Readers. This is because connecting one Wiegand reader requires all four pins 
on plug PB. For example, if you connect a Prox Mifare Series (Teardrop) 
reader to Port 1 of Group 1, Port 2 of Group 1 can only connect to another 
Cardax IV reader. 

The terminating resistors (J1 for Group 1, J2 for Group 2, etc.) must NOT be 
fitted for those groups to which Prox Mifare Series (Teardrop) readers are 
connected. 
 

Configuration 

The Prox Mifare Series (Teardrop) reader is configured as a “Cardax IV 
Reader” in Cardax FT Command Centre. 
No specific initialisation or hardware configuration is required. 
 

Содержание Prox Mifare Series

Страница 1: ...ferent lengths WARNING You must use the screws provided as using other types of screws could interfere with the electronics See the Mounting section later for further explanation Firmware Version vMT3...

Страница 2: ...ort tail of this cable is supplied with connector fitted with each reader When using a single cable to carry both power supply and data from the source to the reader both the power supply voltage drop...

Страница 3: ...than 200mm away Mounting Note The Prox Mifare Series Teardrop reader has been designed to metric specifications Therefore any imperial measurements provided are approximate only The Prox Mifare Series...

Страница 4: ...lding cabling through the base and grommet Fit the base to the 20 mm 3 4 inch hole and secure it to the mounting surface using two of the fixing screws provided Note The surface the reader is being at...

Страница 5: ...he inside surface of the reader base Install the PCB assembly into the base Fit the facia onto the base by clipping the small lip inside the facia over the top edge of the base and holding the top pre...

Страница 6: ...00 4R Cardax FT Controller 3000 Use the cable terminating tool to connect the cables to the socket as described in the following sections Pin number 4 of the Prox Mifare Series Teardrop reader connect...

Страница 7: ...4 on the Controller 3000 Each group provides connection for two Prox Mifare Series Teardrop readers or other Cardax IV readers Refer to the following diagram for the location of the ports on the Carda...

Страница 8: ...egand Readers This is because connecting one Wiegand reader requires all four pins on plug PB For example if you connect a Prox Mifare Series Teardrop reader to Port 1 of Group 1 Port 2 of Group 1 can...

Страница 9: ...a Cardax IV reader within the Cardax FT Command Centre system Initialising with the Cardax FT Controller 3000 4R or 3000 Refer to the appropriate Installation Note for initialization instructions Card...

Страница 10: ...equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Note C...

Страница 11: ...re Series Teardrop reader should only be cleaned with clean lint free damp cloth Power required Voltage 13 6 15 V DC Current 125mA Reading range Up to 30mm depending on card type and installation cond...

Страница 12: ...12 Part number 3E1100 R16 July 2010 Mounting Dimensions 17 mm 39 mm 51 mm 51 mm 20 mm Pilot hole Pilot hole 20 mm hole Slot...

Отзывы: