background image

R38 Controller 

 

 

3.1.

 

Overtemperature Control (if fitted) 

 

The hydraulic thermostat overtemperature controller should typically be set at 15°C above the 
main controller. If an overtemperature condition occurs, always investigate the possibility that 
the main control system has failed. 

 

An overtemperature condition always cuts off power to the heating elements. To reset the 
condition, first either allow the oven to cool, or increase the overtemperature setting. 

 

If the overtemperature trip operates then a click occurs and a warning light near the thermostat 
lights up; the reset button on the thermostat pops out. The reset button is hidden behind the 
control dial: to reset the oven it is necessary to turn the thermostat dial till the hole lines up with 
the reset button and press it using a small diameter rod. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 