![Capstan Turf Sprayer Edition SharpShooter With Rate Sync Скачать руководство пользователя страница 23](http://html1.mh-extra.com/html/capstan/turf-sprayer-edition-sharpshooter-with-rate-sync/turf-sprayer-edition-sharpshooter-with-rate-sync_operator-and-maintenance-manual_2554691023.webp)
SharpShooter
®
with Rate Sync
®
- Turf Sprayer Edition
©2003, 2011, 2015 Capstan Ag Systems, Inc., All Rights Reserved | Version:
P-3.0
| 6/9/2016
3.0 - Parts Identification
21
3.14 - Nozzle Valve Assembly
[Figure 19]
- The SharpShooter pulses the Nozzle
Valve Assembly to maintain a constant boom and tip
pressure.
The Nozzle Valve Assembly screws onto the nozzle
bodies replacing the standard diaphragm check valve.
The 2 pin Packard connector plugs into boom harness
from the Power Hub.
3.15 - Tips
[Figure 20]
- Capstan offers Wilger pre-orifice drift
reduction tips.
Depending on the top spraying speed desired, Capstan
offers:
•
SR110-10 - inside nozzle bodies.
•
MR110-10 - outer BOOST nozzle bodies.
•
MR110-125 tips are used to replace the MR110-10
tips when application rates exceeding 2.0 gal/
1000sf are consistently used. Additional tips may
be ordered as necessary.
•
SR110-06 tips are used to replace the SR110-10
tips when application rates less than 1.0 gal/1000sf
are consistently used.
Figure 19: Nozzle Valve Assembly
Figure 20: Tips
This part requires a Wilger brand
nozzle body. Do not replace broken
nozzle bodies with a brand other than
Wilger as significant leaking will
occur.
ITEM
PART NO.
DESCRIPTION
1
116189-111
Coil
2
716009-111
Plunger
3
715022-204, Size-015
O-ring
4
717101-007
Flynut
5
116188-111
Valve Body
6
715022-201, Size-008
O-ring
7
715022-206, Size-016
O-ring
These tips have the same inlet orifice
that determines the maximum flow.
But the two tips have different exit
orifices to allow a broader droplet
spectrum.
116390-111
1
3
5
2
4
6
7
Nozzle Valve
Assembly
Nozzle Body
132010-001
132009-001
SR110-10
MR110-10