Use only 11 kg or 5 kg gas bottles. Camping gas bottles with built-in
check valve (blue bottle with max. 2.5 or 3 kg content) are can be
used in exceptional cases with a safety valve.
Use the shortest possible tube lengths (150 cm max.) for external gas
bottles.
Never block the floor ventilation openings below the gas bottles.
The screw connections on the gas bottles generally have a left-hand
thread.
For gas-operated units the gas pressure must be reduced to 30 mbar.
Connect gas pressure regulator complete with safety valve directly to
bottle valve.
For filling and connecting the gas bottles in Europe the accessories
shops have corresponding Euro filling sets and Euro bottle sets.
Information available at the dealers or service centre.
The gas pressure regulator reduces the gas pressure in the gas bottle down
to the operating pressure of the gas devices.
The gas pressure regulator is permanently installed in the gas bottle com-
partment. The gas bottle is connected to the gas pressure regulator via a
high-pressure gas hose.
The high-pressure gas hoses and their connections are different in the vari-
ous countries. The accessories shop offers the respective country-specific
models and adapters.
7.3 Gas
pressure
regulating system DuoControl CS
The regulating system and the hose lines shall be changed at the latest
10 years after manufacturing date. The operator is responsible for this.
Also read the manufacturer's instruction manual.
DuoControl CS is a safety gas pressure regulating system with automatic
switching for a two-bottle gas system and with crash sensor. The DuoCon-
trol regulating system automatically switches the gas supply from the pri-
mary bottle to the reserve bottle as soon as the primary bottle is either
empty or no longer ready for operation. The gas appliances may still con-
tinue operation. The DuoControl regulating system is suitable for all com-
mercial gas bottles with liquefied gas (propane/butane) and a pressure of
0.6 bar to 16 bar.
The DuoControl regulating system ensures a constant gas pressure for the
gas-operated devices, no matter which gas bottle is supplying the gas.
In the event of an accident, the crash sensor in the DuoControl regulating
system will interrupt the gas flow.
The gas bottles are connected via high pressure hoses. A hose break guard
prevents gas leakage in the event of a damaged hose.
The operation of gas-operated devices during the journey is permitted in all
of Europe if the vehicle is equipped with a gas pressure regulating system
with crash sensor and high-pressure hoses with hose break guard.
Содержание Sunlight A68 2018
Страница 4: ...Contents 4 2999828 05 18 EHG 0012 00EN ...
Страница 8: ...Introduction 8 2999828 05 18 EHG 0012 00EN 1 ...
Страница 26: ...Before the journey 26 2999828 05 18 EHG 0012 00EN 3 ...
Страница 32: ...Pitching the Motorcaravan 32 2999828 05 18 EHG 0012 00EN 5 ...
Страница 58: ...Gas system 58 2999828 05 18 EHG 0012 00EN 7 ...
Страница 74: ...Electrical system 74 2999828 05 18 EHG 0012 00EN 8 ...
Страница 118: ...Wheels and tyres 118 2999828 05 18 EHG 0012 00EN 13 ...
Страница 132: ...Helpful notes 132 2999828 05 18 EHG 0012 00EN 15 ...