8
transportation, and the oil form the jetting noise in the capillary.
Solution: Clean the cooling system pipe, and recharge with refrigerant see
(
→
2)
▲
Evaporator freezing
○
Because the gasket is not air-proof, or the door is not closed well, cause much water fill in the the
cabinet, and the water got frozen when it encounter the cold air, sometimes the ice is too thick, and it will
block the fan or broken the fan.
The solution:
1>. Replace the door gasket or close the door well. If the door gasket is slightly not air-proof, it can be
repaired by the heat dryer.
Aiming at the distortion of the gasket with the heat dryer, and move up and down or right and left
until it expand to the normal state. When it is cool, check it with the door closed, if there is any
distortion, dry it again until it fix for the door.
(Fig.7)
▲
The instability of the wine cooler temperature
The unstable temperature is caused by the evaporator fans cease, and it can be check by the below method: When
the compressor is running, the light
“
Run
”
is on, the fan should be running, if the fan stop, check whether is any
fault in the fan or fan connection. If the fan is broken, replace it with the fan of the same model.
(Fig.5)
▲
The control system fault
○
Fault finding by self-check mode
This series wine cellar has a computerized controller with built in self-check function. Start the
self-check mode as follows:
1>. Press and hold
“
Set lower
”
and
“
Set upper
”
button with power on. 3 beeps will sound, and then the
controller will start the self-check function.
2>. If everything is operating correctly,
a.
No response when pressing buttons.
b.
LED display
”
━
━
”
;
c.
The compressor works and the
“
RUN
”
indicator light are on all the time.
d.
The condenser and evaporator fans work at full speed,the valve switch every three seconds;
Fig. 7