19
Please keep this instruction manual for future reference
Instruction manual VEL410BK/CO/GD
T R O U B L E S H O OT I N G
FAU LT
C AU S E
S O L U T I O N
The lights on, but the
fan does not work
The fan blade is jammed.
Switch off the unit and contact
Caple Service. To be repaired by qualified
service personnel only.
The motor is damaged.
The lights and fan
do not work
A blown fuse.
Replace the fuse.
The power cord is loose.
Ensure the extractor is correctly connected to
the mains power supply.
Serious vibration of
the unit
The fan blade is damaged.
Switch off the unit and contact
Caple Service. To be repaired by qualified
service personnel only.
The fan motor is not fixed tightly.
Switch off the unit and contact
Caple Service. To be repaired by qualified
service personnel only.
The unit is not hung correctly on the
bracket.
Take down the unit and check whether the
bracket is in the correct location.
The extraction
performance
is not good
The filter requires cleaning or there is too
greater distance between the hood and
the hob
Clean the grease filter as directed in the
‘Care and maintenance’ section. Replace
the charcoal filter. Readjust the distance of
the hood so that it is 65-75cm from the
hob below.
If the above table has not solved the problem please contact Caple Service by phone on
0117 938 7420
or by email
Содержание Vela VEL410BK
Страница 21: ...21 Please keep this instruction manual for future reference Instruction manual VEL410BK CO GD ...
Страница 22: ...22 Please keep this instruction manual for future reference Instruction manual VEL410BK CO GD NOTES ...
Страница 23: ...23 Please keep this instruction manual for future reference Instruction manual VEL410BK CO GD NOTES ...
Страница 24: ...Caple Service Fourth Way Avonmouth Bristol BS11 8DW T 0117 938 1900 E service caple co uk www caple co uk ...