background image

Instruction manual FSCHSS9

13

Please keep this instruction manual for future reference 

A I R   E X T R A C T I O N   S E T T I N G

D U C T E D   I N S TA L L AT I O N : 

Turn the adjuster to the ducted position, install the outlet, turn on the cooker hood. The air will be 
extracted to the outside outlet.

R E C I R C U L AT I O N : 

The recirculation mode uses a CAP80CF charcoal filter. Turn the adjuster to the indoor position, 
install the outlet cover onto the round ducting spigot, turn on the cooker hood, then the air can be 
vented from the front outlet.

N O T E :

We recommend the ducting does not exceed 2.5 metres in length, to ensure maximum efficiency.





























            





The  recirculation  mode  uses  a  C

CA

APP6622C

CFF  

charcoal

 

Note: The charcoal filter is mounted on the back of the grill and must 

be changed once every 6 months. Replacement CAP62CF charcoal 

filters can be purchased directly from www.caple.co.uk.

Warning: the charcoal filter cannot be washed or recycled. It should 

be changed at most after 120 hours of use. The charcoal filter 

shouldn’t be exposed to heat. 

To install the filters, simply line up the lugs and push onto the 

motor. Then twist to lock and secure to the filters.

Содержание FSCHSS9

Страница 1: ...Conventional Hood Instruction manual FSCHSS9 Contact Caple on 0117 938 7420 for spare parts or www caple co uk ...

Страница 2: ...future reference CO NTE NT S Introduction 3 Safety Instructions 4 Environmental Protection 9 Installation 10 Air Extraction Setting 13 Installing the Charcoal Filter 14 Operation 15 Care and Maintenance 16 Troubleshooting 18 Product Dimensions 19 Caple Contact Details 20 ...

Страница 3: ... appliance or visit www caple co uk and register here This instruction manual is designed to provide you with all the required information related to the installation use and maintenance of the appliance This hood is designed to extract unpleasant odours from the kitchen it is not intended to extract steam In order to operate the unit correctly and safely please read this instruction manual carefu...

Страница 4: ...in fire electric shock or injury To protect against fire electrical shock and injury to persons do not immerse cords or plugs in water or any other liquid Never touch the appliance with wet or damp hands Never pull the power cable as you could damage it If the appliance is faulty do not attempt to repair it Isolate it from the mains electric supply and contact Caple Service either by phone 0117 93...

Страница 5: ...et children operate the machine The cooker hood is for home use only not suitable for barbecuing restaurants or other commercial purposes The cooker hood and its filter should be cleaned regularly in order to keep in good working condition Clean the cooker hood according to the instruction manual to reduce the risk of fire When using a gas hob do not leave naked flames under the extractor Before c...

Страница 6: ...air in the kitchen is being circulated before cooking commences and the air is being cleaned after cooking has finished The performance of your extractor will vary depending on a number of factors These include type of extraction room volume length of ducting ventilation available and the cleanliness of the filters This appliance is not intended for use by persons including children with reduced p...

Страница 7: ... environments Bed and breakfast type environments To avoid all risk if the power cable is damaged it must only be replaced by a Caple appointed engineer Appliances can be used by persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards ...

Страница 8: ...must be connected to the mains by a competent person We recommend that the appliance is connected by a qualified electrician who is a member of the N I C E I C who will comply with the I E E and local regulations Electrical information can be found on the rating plate As this appliance is Class II As this appliance is Class II the extractor does not need any earth connection the extractor does not...

Страница 9: ...ur local council your household waste disposal service or the retailer where you purchased the product WARRANTY Your new appliance is covered by warranty The warranty card is enclosed if it is missing you must provide the following information to your retailer in order to receive a replacement date of purchase model and serial number Registration can also be completed online by visiting www caple ...

Страница 10: ...t with an interior diameter of 120mm Before installation turn the unit off and unplug it from the outlet The cooker hood should be placed at a minimum distance of 65 76cm above the hob It is the manufacturer of the hob who determines the clearance required and the clearance quoted by the hob manufacturer must be followed In the absence of any instructions supplied with a gas hob the minimum distan...

Страница 11: ...of hole in the back of the cooker hood 2 Insert the wall plugs into the holes 3 Insert the screws into the wall plugs and tighten Put the cooker hood onto the tightened screws 4 Mark position for the safety screw holes onto the wall and remove the cooker hood 5 Drill 2 holes of Ø8mm and insert wall plugs into holes 6 Place the cooker hood onto the tightened screws see A 7 Fix the cooker hood with ...

Страница 12: ...4 holes of 6mm diameter at the bottom of the hanging cupboard Attach the one way valve to the cooker hood then install the cooker hood onto the bottom of the cupboard tighten the hood with the 4 screws supplied NOTE The ducting tube is not supplied with the extractor Take off the protective film before installation ...

Страница 13: ...the air can be vented from the front outlet NOTE We recommend the ducting does not exceed 2 5 metres in length to ensure maximum efficiency The recirculation mode uses a C CA AP P6 62 2C CF F charcoal Note The charcoal filter is mounted on the back of the grill and must be changed once every 6 months Replacement CAP62CF charcoal filters can be purchased directly from www caple co uk Warning the ch...

Страница 14: ...nce every 6 months Replacement CAP80CF charcoal filters can be purchased directly from www caple co uk WARNING the charcoal filter cannot be washed or recycled It should be changed at most after 120 hours of use approximately 6 months The charcoal filter shouldn t be exposed to heat To install the filters simply line up the lugs and push onto the motor Then twist to lock and secure to the filters ...

Страница 15: ...ow fan speed It is suitable for simmering and cooking which does not produce much steam or odour MEDIUM SPEED BUTTON Press this button to select the medium fan speed The airflow speed is ideal for extracting with standard cooking HIGH SPEED BUTTON Press this button to select the high fan speed When a high amount of steam or odours are produced use the high speed setting for the most effective extr...

Страница 16: ...e grease residue which is potentially flammable will saturate the filter It can be easily cleaned with warm water and washing up liquid alternatively the filters can be cleaned in your dishwasher Please ensure no other items are washed with the filters they must be washed separately to prevent food becoming trapped in the gauze Cleaning the grease filters in the dishwasher may lead to discolourati...

Страница 17: ...amp cover by unscrewing the 2 screws 4 Unclip the light and remove by pressing the metal retaining clips and pushing down 5 Open clip box a and unplug light 6 Replace with the same type and rated bulb 2W by following these instructions in reverse Clip box Lamp cover Retaining Clips Aluminium Grease Filters Light a LIGHT SOURCE ENERGY CLASS This product contains a light source of energy efficiency ...

Страница 18: ...nit and contact Caple Service To be repaired by qualified service personnel only The fan motor is not fixed tightly Switch off the unit and contact Caple Service To be repaired by qualified service personnel only The unit is not hung correctly on the bracket Take down the unit and check whether the bracket is in the correct location The extraction performance is not good The filter requires cleani...

Страница 19: ...Instruction manual FSCHSS9 19 Please keep this instruction manual for future reference P RODUCT D IM ENSIONS 140mm 600mm 340mm 500mm 120mm ...

Страница 20: ...Caple Service Fourth Way Avonmouth Bristol BS11 8DW T 0117 938 1900 E service caple co uk www caple co uk ...

Отзывы: