Instruction manual C847i
26
Please keep this instruction manual for future reference
Check with an electrician whether the domestic wiring system is suitable without alterations. Any
alterations must only be made by a qualified electrician.
The power supply should be connected in compliance with the relevant standard,or a single-pole
circuit breaker. The method of connection is shown below.
-
If the cable is damaged or to be replaced, the operation must be carried out the by after-sale
agent with dedicated tools to avoid any accidents.
-
If the appliance is being connected directly to the mains an omnipolar circuit-breaker must be
installed with a minimum opening of 3mm between contacts.
-
The installer must ensure that the correct electrical connection has been made and that it is
compliant with safety regulations.
-
The cable must not be bent or compressed.
-
The cable must be checked regularly and replaced by authorised technicians only.
220-240V~
25A~
Yellow / Green
Black
Brown
Blue
220-240V~
2
3
4
5
N1
L2
L1
N2
1
Yellow / Green
Black
Brown
Blue
380-415V~
220-240V~
220-240V~
2
3
4
5
N1
L2
L1
N2
1