19
Instruction manual C775G, C750G, C768G
Please keep this instruction manual for future reference
I N S TA L L AT I O N I N S T R U C T I O N S
Neglect of this mark may result in severe personal injury or death.
Danger/Warning
Neglect of this mark may result in minor personal injury or
property damage.
No naked flames
No Access
Must Do
DANGER
If gas appears to be leaking, take the following actions:
-
Do not turn on the light.
-
Do not switch any electrical appliance on or off and do not touch any electric plug.
-
Do not use a telephone.
1 Stop using the product and close the middle valve.
2 Open the window to ventilate.
3 Contact our service centre or gas supplier by using a phone outside.
* The gas contains mercaptan, so that you can smell the gas leak (smell of rotten garlic or egg) even where only
1/1000 of the gas is in the air.
WARNING SYMBOLS
Caution
WARNINGS
› Do not modify this appliance.
› This appliance must be installed by an authorised technician or installer.
› Prior to installation, ensure the local distribution conditions (nature of the gas and gas
pressure) and the adjustment of the appliance are compatible.
› The adjustment conditions for this appliance are stated on the label (or Rating Label).
› This appliance is not connected to a combustion product evacuation device. It should be
installed and connected in accordance with current installation regulations. Particular
attention should be given to the relevant requirements regarding ventilation.
› Before installing, turn off the gas and electricity supply to the appliance.
› All appliances containing any electrical components must be earthed.
› Ensure that the gas pipe and electrical cable are installed in such a way that they do not
touch any parts of the appliance which may become hot.
› The gas pipe or connector shouldn’t be bent or blocked by any other appliances.
› Check the dimensions of the appliance as well as the dimensions of the gap to be cut in the
kitchen unit.
› The panels located above the work surface, directly next to the appliance, must be made
of non-flammable material. Both the work surface and the glue used to secure it should be
heat resistant, to prevent deterioration.
› Turn on the appliance tap and light each burner. Check for a clear blue flame without yellow
tipping. If the burners show any abnormalities check the following:
- Burner lid is on securely.
- Flame spreader is positioned correctly.
- Burner is vertically aligned with injector nipple.
› A full operational test and a test for possible leakages must be carried out by the fitter after
installation.
› The flexible hose shall be fitted in such a way that it cannot come into contact with a
moveable part of the housing unit and does not pass through any space susceptible of
becoming congested. The hose must be manufactured in accordance with BS669 part 1 and
be of the correct construction for the type of gas being used. Gas hoses designed for natural
gas MUST NOT be used for supplying LPG gas (LPG gas hoses can be identified by either a
red band or stripe on the rubber outer coating of the hose).
› The installation must confirm to all current installation standards and regulations in force.