Curvation & Siesta Series Manual - V2.2
© Capital Fireplaces 2017
4
2. User instructions
2.1 Emergency Gas Isolation
In the event of a gas leak or if gas is smelt, the appliance must be isolated. This is done by turning OFF
the gas at the Isolation Tap. This Isolation Tap is located in the foot of the appliance.
2.2 First Time of Operation
Before igniting the appliance, ensure that all packaging, safety stickers and any protective wrapping
have been removed, and that the glass has been cleaned, including all fingerprints from the glass.
Ensure that the room is adequately ventilated the first time that the appliance is ignited; we would
recommend opening windows if possible. Run the appliance at full setting for a few hours so that the
paint gets an opportunity to fully cure. During this period it is possible for some fumes and vapours to
be given off. We would recommend keeping children and pets out of the area at this time.
2.3 Control Overview
2.3.1 Basic Manual Control
1. Igniting the Pilot Light
a
) From the OFF position, depress the control knob for five
seconds (only pilot gas flows).
b) Turn the control knob anti-clockwise through the PILOT
position and continue turning until the igniter “clicks”, if the Pilot
flame lights, hold for ten seconds (only pilot gas flows). If the
Pilot has not Ignited, return the control knob to the OFF position
and repeat.
c) Upon releasing the control knob the pilot flame should remain
alight, if not return the control knob to the OFF position and
repeat.
2. Igniting the Main Burner
The appliance should always be run on FULL for the first 30 seconds.
From the IGNITION position, turn the control knob fully anti-
clockwise, this is the FULL position, gas should now be flowing to
the main burner and the burner should light on full.
3. Adjusting the Flame Height (heat setting)
From the FULL position, turn the control clock-wise, until the control
knob reaches a stop, this is the LOW setting. Any position between
HIGH and LOW can be selected as an intermediate setting.
Содержание Curvation:Siesta
Страница 7: ...Curvation Siesta Series Manual V2 2 Capital Fireplaces 2017 7 ...
Страница 8: ...Curvation Siesta Series Manual V2 2 Capital Fireplaces 2017 8 ...
Страница 9: ...Curvation Siesta Series Manual V2 2 Capital Fireplaces 2017 9 ...
Страница 10: ...Curvation Siesta Series Manual V2 2 Capital Fireplaces 2017 10 ...
Страница 26: ...Curvation Siesta Series Manual V2 2 Capital Fireplaces 2017 26 Siesta Tall Siesta model with side windows ...
Страница 27: ...Curvation Siesta Series Manual V2 2 Capital Fireplaces 2017 27 Appendix 1 Mertik Fault Finding Chart ...
Страница 28: ...Curvation Siesta Series Manual V2 2 Capital Fireplaces 2017 28 ...
Страница 29: ...Curvation Siesta Series Manual V2 2 Capital Fireplaces 2017 29 ...