The following 

COMMAND

 table describes the available commands:  

Flash count

 

Command

 

Description

 

1 flash 

STATUS 

Shows  the  device  STATUS.  As  answer  the  led  perform  a  flash  sequence  as 
reported in the “STATUS” table. If the device is performing the TEST (

refer to TEST 

command

) this command stops it.  

2 flashes 

TEST 

Enter in TEST mode and transmits status and measurements every 5 seconds. If 
the device is in STANDBY mode or it is out of radio range, this command forces 
the connection procedure to the WSN and the return to the operative mode. The 
TEST  stops  after  120  seconds.  During  TEST  the  led  continuously  shows  the 
STATUS to monitor the received radio signal quality. 

CAUTION: Measures acquired during 

TEST

 phase are NOT saved.

 

3 flashes 

ENROLL 

Association  to  the  network:  must  be  used  when  the  device  has  not  yet  been 
included  in  a  network,  starts  the  entry  and  association  procedure  to  the 

basestation

 (

refer to “

WineCap System - User Manual R29

). 

4 flashes 
  
 
+ 4 flashes 

STANDBY 

Temporary device deactivation: the device is stopped. The sampling process and 
the radio are/is turned off losing the connection to the network. To reactivate, a 
TEST  command  is  necessary.  The  STANDBY  command  must  be    given  twice  to 
confirm it: at the first sequence the led flashes alternating RED and GREEN lights, 
waiting  for  the  second  confirm  sequence  within  15  seconds.  At  the  command 
execution the led flashes as the STANDBY status (

refer  to 

WIRELESS MODE STATUS 

Table

). 

5 flashes 
 
 
+ 5 flashes 

FACTORY 

RESET 

The device performs the memory deleting procedure and goes in STOP status. All 
samples,  configuration  and  wireless  network  data  associated  are  LOST.  To 
reactivate the device a new association and configuration procedure is necessary 
(

ENROLL command

). Also in this case, the FACTORY RESET command must be given 

twice  to  confirm  it.  At  the  command  execution  the  led  flashes  as  the 
“PROBE/DATALOGGER  NOT  ASSOCIATED”  status 

refer  to  

WIRELESS  MODE  STATUS 

Table

). 

5 flashes 
 
 
+ 3 flashes 

LOGGER      

NO WSN 

As  the  previous  command  but  performs  only  the  WSN  deleting  procedure  and 
disassociate  from  the 

basestation

.  The  device  enter  in  LOGGER  STAND  ALONE 

mode: data are  kept and the sampling activity CONTINUES with previous setup. 
Command must be given with 2 sequences: 5 flashes and then 3 flashes. At the 
command  execution  wait  for  the  device  reboot.    At  the  STATUS  command, 
“LOGGER” will be the answer (

refer  to  

STAND-ALONE  MODE  STATUS  Table

). A new 

association (

ENROLL command

) is possible to a new 

basestation

 

 

 

Picture 8 - Commands table

 

Содержание WSD15TIIDR

Страница 1: ...ti it 1 11 1 Description The WSD15TIIDR is a datalogger with 3 input channels to acquire Biaxial inclination and Outdoor temperature with storage functionality of samples acquired 2 Configuration Printed on the external label the correspondence between the measured axes and the number of recorded measure channels is reported by means of the three icons below Picture 1 Product Image X X Picture 2 W...

Страница 2: ... ELECTRONIC LEVEL feature Working on slab s regulation sensor position can be corrected and the device can be placed as vertical as possible NOTE antenna must be facing downwards 2 1 ELECTRONIC LEVEL feature Activate the axis reset procedure for channel 2 placing the WineCapKey in the upper left corner and counting 6 amber flashes Led will flash based on the measured tilt RED flashes or GREEN flas...

Страница 3: ...nd instance of the command stores the current position as initial offset In case of an unintentional reset it is always possible to place again the tool near the mechanical zero using ELECTRONIC LEVEL feature and repeat the reset process WineCapManager software shows and if necessary reset the offset stored in the datalogger using a remote radio command ELECTRONIC LEVEL and RESET READING features ...

Страница 4: ...is operation mode stand alone with data downloads through USB the connection with the PC and the WineCapManager running on it is necessary in order to modify the device s operation mode The sampling interval must be set with the device in STAND ALONE refer to Stand alone USB datalogger installation mode and automatically the device s clock is aligned with the PC s clock in order to assure the temp...

Страница 5: ... it web www capetti it 5 11 4 Wireless device user interface The user interface consists of a virtual button that can be activated using the WineCapKey and of a two coloured led To give a command user must approach the WineCapKey to the device s sensible area and keep it in that position the following picture Picture 7 WineCapKey positioning shows device s sensible points Picture 7 WineCapKey posi...

Страница 6: ...topped The sampling process and the radio are is turned off losing the connection to the network To reactivate a TEST command is necessary The STANDBY command must be given twice to confirm it at the first sequence the led flashes alternating RED and GREEN lights waiting for the second confirm sequence within 15 seconds At the command execution the led flashes as the STANDBY status refer to WIRELE...

Страница 7: ...different command is associated to confirm the command the WineCapKey must be removed from the sensible area immediately after the number of flashes corresponding at the desired command The TEST corresponds to the second pulse and activate the Field Measurer function The device will give back the radio signal quality through led flashes WIRELESS MODE STATUS Table Flash count Wireless mode Status R...

Страница 8: ...sh count Stand alone mode STATUS 1 green flash 2 seconds long ACTIVE 2 red flashes 2 seconds long STANDBY Sequence of red flashes short 2 seconds long short FACTORY RESET INVALID datalogger clock PC connection required 8 Shutting off Reactivating the device If the device is shut off and left unused for a long time you can issue the STANDBY command refer to Picture 8 Commands table Its corresponds ...

Страница 9: ...mensions 100x100x80mm Weight 1 6000g Case material Aluminium Mounting Wall mounting with 2 gross setting Connections Wireless USB Inclination Transducer type Uniaxial Biaxial Triaxial MEMS technology 1 15 Dual Range Automatic Autoscale Inclination Measure range 1 15 Inclination Measure accuracy 0 5 of sample Inclination Measure resolution 0 001 1 range 0 01 15 range Inclination Mechanical zero adj...

Страница 10: ..._R11 V4 7 CAPETTI ELETTRONICA s r l Strada Stratta 57 10090 CASTIGLIONE TORINESE TORINO ITALY VAT 04837130014 Phone 011 981 98 11 Fax 011 981 98 210 e mail info capetti it web www capetti it 10 11 10 Mechanical dimensions Picture 11 Mechanical dimensions ...

Страница 11: ...11 65 CE that restricts the use of substances in the manufacturing of electronic devices The WEEE logo on the label indicates that this product is compliant with the WEEE EC Directive This symbol valid only in the European Union countries indicates that the product it is applied to MUST NOT be discarded with ordinary household or industrial waste but must be sent to an authorized reception point T...

Отзывы: