5.

 

Enrolling the device. 

Not necessary if performed in factory before delivery. 

Enroll the device to the network referring to the 

WineCap System - User Manual R29

. In case the device is already enrolled but in 

STANDBY

 status, a 

TEST

 command must be issued (

refer t

Picture 8 - Commands table

).

 

6.

 

Installation procedure. 

After installing the 

basestation

 in appropriate place in charge, (

refer to 

WineCap System - User Manual R29

), be sure that the device is 

enrolled to the 

basestation

 and activated. 

Head  for  the  environment  to  be  monitored.  On  the  way,  to  check  the  quality  of  the  radio  coverage,  use  the  "

Field  Measurer

"  

function. 

This  function  is  activated  issuing  the 

TEST

  (

refer  to 

Picture  8  -  Commands  table

)command:  position  the 

WineCapKey

  in  the  spot 

indicated in 

Picture 7 - WineCapKey positioning

 and wait for two 

AMBER

 flashes, then remove the 

WineCapKey

 from device. The 

"

Field Measurer

" function  lasts enabled for two minutes.  

To issue commands to the device, place the 

WineCapKey

 where indicated. 

Once the 

WineCapKey

 is detected, the led periodically emits 

AMBER

 flashes with a 2 seconds cadence.  

For each flash, a different command is associated; to confirm the command the 

WineCapKey

 must be removed from the sensible 

area immediately after the number of flashes corresponding at the desired command. The 

TEST

 corresponds to the second pulse 

and activate the "

Field

 

Measurer

" function.

 

 

The device will give back the radio signal quality through led flashes: 

WIRELESS MODE STATUS

 Table 

Flash count - Wireless mode 

Status/Radio signal quality 

 

5 green flashes 

Excellent 

 

4 green flashes

 

Good

 

 

3 green flashes

 

Fair

 

 

2 amber flashes

 

Sufficient

 

 

1 red flash 

Insufficient 

 

1 red flash 2” long 

OUT OF RANGE 

Network searching 

 

2 red flashes 2” long 

STANDBY 

 

Short-long-short red 

flashes series  

FACTORY RESET 

Device not enrolled

 

 

Optimize reception selecting the best position: small movements can help. 

If the signal is absent or insufficient at the install point, 

WR12

 

router

 should be put between (

refer to 

WineCap System - User Manual 

R29

). Th

WR12

 

router

 

itself must be located in a position where the signal level is at least sufficient. 

The network will reconfigure itself automatically; the signal will be good again when the device synchronizes with the 

WR12

 

router

The link will not be reconfigured until completely lost by the device. Because of this, in some cases it could be necessary to force 
the operation. In such cases, put the device in 

STANDBY

 mode, then run the 

TEST

 again (

refer to “

WineCap System - User Manual R29

). 

NOTE

: The display equipped 

datalogger

 (

WD04T

) is recommended, to verify the signal quality during devices installation. 

 

 

Picture 9 - Status table - Radio signal quality

 

Содержание WSD15TIIDR

Страница 1: ...ti it 1 11 1 Description The WSD15TIIDR is a datalogger with 3 input channels to acquire Biaxial inclination and Outdoor temperature with storage functionality of samples acquired 2 Configuration Printed on the external label the correspondence between the measured axes and the number of recorded measure channels is reported by means of the three icons below Picture 1 Product Image X X Picture 2 W...

Страница 2: ... ELECTRONIC LEVEL feature Working on slab s regulation sensor position can be corrected and the device can be placed as vertical as possible NOTE antenna must be facing downwards 2 1 ELECTRONIC LEVEL feature Activate the axis reset procedure for channel 2 placing the WineCapKey in the upper left corner and counting 6 amber flashes Led will flash based on the measured tilt RED flashes or GREEN flas...

Страница 3: ...nd instance of the command stores the current position as initial offset In case of an unintentional reset it is always possible to place again the tool near the mechanical zero using ELECTRONIC LEVEL feature and repeat the reset process WineCapManager software shows and if necessary reset the offset stored in the datalogger using a remote radio command ELECTRONIC LEVEL and RESET READING features ...

Страница 4: ...is operation mode stand alone with data downloads through USB the connection with the PC and the WineCapManager running on it is necessary in order to modify the device s operation mode The sampling interval must be set with the device in STAND ALONE refer to Stand alone USB datalogger installation mode and automatically the device s clock is aligned with the PC s clock in order to assure the temp...

Страница 5: ... it web www capetti it 5 11 4 Wireless device user interface The user interface consists of a virtual button that can be activated using the WineCapKey and of a two coloured led To give a command user must approach the WineCapKey to the device s sensible area and keep it in that position the following picture Picture 7 WineCapKey positioning shows device s sensible points Picture 7 WineCapKey posi...

Страница 6: ...topped The sampling process and the radio are is turned off losing the connection to the network To reactivate a TEST command is necessary The STANDBY command must be given twice to confirm it at the first sequence the led flashes alternating RED and GREEN lights waiting for the second confirm sequence within 15 seconds At the command execution the led flashes as the STANDBY status refer to WIRELE...

Страница 7: ...different command is associated to confirm the command the WineCapKey must be removed from the sensible area immediately after the number of flashes corresponding at the desired command The TEST corresponds to the second pulse and activate the Field Measurer function The device will give back the radio signal quality through led flashes WIRELESS MODE STATUS Table Flash count Wireless mode Status R...

Страница 8: ...sh count Stand alone mode STATUS 1 green flash 2 seconds long ACTIVE 2 red flashes 2 seconds long STANDBY Sequence of red flashes short 2 seconds long short FACTORY RESET INVALID datalogger clock PC connection required 8 Shutting off Reactivating the device If the device is shut off and left unused for a long time you can issue the STANDBY command refer to Picture 8 Commands table Its corresponds ...

Страница 9: ...mensions 100x100x80mm Weight 1 6000g Case material Aluminium Mounting Wall mounting with 2 gross setting Connections Wireless USB Inclination Transducer type Uniaxial Biaxial Triaxial MEMS technology 1 15 Dual Range Automatic Autoscale Inclination Measure range 1 15 Inclination Measure accuracy 0 5 of sample Inclination Measure resolution 0 001 1 range 0 01 15 range Inclination Mechanical zero adj...

Страница 10: ..._R11 V4 7 CAPETTI ELETTRONICA s r l Strada Stratta 57 10090 CASTIGLIONE TORINESE TORINO ITALY VAT 04837130014 Phone 011 981 98 11 Fax 011 981 98 210 e mail info capetti it web www capetti it 10 11 10 Mechanical dimensions Picture 11 Mechanical dimensions ...

Страница 11: ...11 65 CE that restricts the use of substances in the manufacturing of electronic devices The WEEE logo on the label indicates that this product is compliant with the WEEE EC Directive This symbol valid only in the European Union countries indicates that the product it is applied to MUST NOT be discarded with ordinary household or industrial waste but must be sent to an authorized reception point T...

Отзывы: