WSD15TIIDR
User Manual
WA0140E_WSD15TIIDR User Manual_R11
V4.7
CAPETTI ELETTRONICA s.r.l. - Strada Stratta 57
10090 CASTIGLIONE TORINESE - TORINO - ITALY
VAT 04837130014 - Phone 011.981.98.11 - Fax 011.981.98.210
e-mail [email protected] - web www.capetti.it
9/11
9.
Technical Information.
Power supply
8.5A/h - 3.6V type “C” lithium internal battery
Battery life (*)
Up to 5years
(samples every 60 minutes and radio signal quality at least sufficient)
Measures acquired
(3 input channels
Biaxial inclination
Outdoor temperature
Sampling interval
(
*
)
Selectable from one minute to 24 hours
(60 minutes default)
Datalogger capacity
64,000 sample
(
for each channel
)
Working temperature
Operative: -30°C ÷ +60°C
Warehousing: -40°C ÷ +70°C
Radio frequency
ISM 868MHz
Radio coverage
Up to 6Km in line of sight
(can be extended using
battery powered routers)
Sealing
IP67
Dimensions
100x100x80mm
Weight
1,6000g
Case material
Aluminium
Mounting
Wall mounting with ±2° gross setting
Connections
Wireless, USB
Inclination - Transducer type
Uniaxial/Biaxial/Triaxial - MEMS technology - 1°÷15° Dual Range
Automatic Autoscale
Inclination - Measure range
±1°/±15°
Inclination - Measure accuracy
± 0.5% of sample
Inclination - Measure resolution
0.001°
(±1° range)
- 0.01°
(±15° range)
Inclination - Mechanical zero adjustment
±4°
Inclination - Cross-axis sensitivity
4% maximum
Inclination - Temperature variation sensibility
±0.013%/°C Temperature balance
Inclination - Shock resistance
20,000g
Inclination - Measure axis
Abscissa
Outdoor temperature - Transducer type
NTC10KΩ
Outdoor temperature - Measure range
-30°C ÷ +60°C
Outdoor temperature - Measure accuracy
± 0.5°C Range -30°C ÷ 0°C
± 0.2°C Range 0°C ÷ +60°C
Outdoor temperature - Measure resolution
0.01°C
* battery life may be influenced by fieldwork conditions, sampling interval and system configuration
.
** radio coverage reachable using up to 32
(maximum 16 for each path) between the device and the basestation.