Product No. 085-1572-0 | Model No. FHWS80023A
30
31
Out of gas
may have been activated
1. Turn control knob to “OFF”
-
ing” section
device:
a. Turn control knob to “OFF”
b. Turn LP gas tank valve to “CLOSED”
c. Disconnect regulator
d. Turn control knob to “ON”
e. Wait one minute
f. Turn control knob to “OFF”
g. Reconnect regulator and leak check connections, being
careful not to fully open valve
New burner may have residual manufacturing oils
Spider webs or insect nest in burner/venturi tube
Clean burner/venturi tube
Poor alignment of valve to burner/venturi tube
Ensure burner/venturi tube is properly engaged with valve
not run the full length of burner
Flame is yellow or orange
Burner and/or burner/venturi tube is blocked
Clean burner and/or burner/venturi tube
High or gusting winds
Low on LP gas
Flame goes out
Flame seems to lose heat when
burning in cold weather — tempera-
ture below 50°F (10°C)
Ice has built up on the outside of the LP gas
tank because the vapourization process is too
slow.
1. Turn off per “Turning Off” section
2. Replace with a spare LP gas tank
3. Reconnect LP gas tank per “Installing LP Gas Tank” section
4. Follow “Checking for Leaks” section
TROUBLESHOOTING
TROUBLESHOOTING
Содержание 085-1572-0