32
33
SILENCE / FP (LOW TEMPERATURE FUNCTION)
Press the SILENCE/FP button for less than 2 seconds to start the SILENCE function, press the button for more
than 2 seconds to start the FP function. This only works in HEAT mode.
SILENCE
•
When the SILENCE function is activated the compressor runs at a lower speed. The air flow from
the indoor unit is also reduced so that the noise level drops, creating an agreeable and almost silent
environment.
Remember! This function may mean that the unit can no longer provide the room with adequate heating/
cooling. In that case deactivate the function.
FP
(low temperature function 8 °C)
•
When the FP function is activated, the indoor unit will try to maintain an indoor temperature of 8 °C instead
of 17 °C, which is the minimum temperature that can be set in HEAT mode.
•
The indoor unit display will show “FP”.
•
Deactivate the function by pressing the SILENCE/FP button again.
Important! At low indoor temperatures it is particularly important to have the basic heat source in operation, set
to approximately 1–2 degrees below the temperature set on the heat pump. This ensures proper operation/
defrosting.
To set the ON timer:
1. Press the TIMER ON button. The remote control display shows TIMER ON with the last set time and “h”.
2. Press the TIMER ON button again to set the time the unit should start. Each press of the button changes the time
by 30 minutes up to 10 hours. After that the time increases 1 hour up to a maximum of 24 hours.
3. After the settings have been made the remote control transmits signals to the indoor unit. After a few seconds “h”
in the display will disappear and the set temperature will be shown.
To set the OFF timer:
1. Press the TIMER OFF button. The remote control display shows TIMER OFF with the last set time and “h”.
2. Press the TIMER OFF button again to set the time the unit should start. Each press of the button changes the
time by 30 minutes up to 10 hours. After that the time increases 1 hour up to a maximum of 24 hours.
3. After the settings have been made the remote control transmits signals to the indoor unit. After a few seconds “h”
in the display will disappear and the set temperature will be shown.
Examples are available on the next page
TURBO
SELF
CLEAN
SLEEP
FRESH
SILENCE
TIMER
ON
TIMER
OFF
LOCK
RESET
LED
FOLLOW
ME
FAN
SPEED
SWING
MODE
TEMP
SWING
1
2
ON/OF F
USING THE ON/OFF TIMER
TIMER ON
Use this function to start the heat pump at a particular time before you get home.
Carry out the following to set the timer, to 6 hours for example:
1. Press TIMER ON; the last time set and “h” are shown in the display.
2. Press TIMER ON again to set “6.0 h” on the display.
3. Wait 3 seconds and the display will show 6.0 h again. The TIMER ON lamp lights and the function is
activated.
Examples of timer settings
TIMER OFF
This function is used to shut down the heat pump, when you have gone to bed for example.
Carry out the following to set the timer, so that the unit shuts down after 10 hours for example:
1. Press TIMER OFF; the last time set and “h” are shown in the display.
2. Press TIMER OFF again to set “10.0 h”" on the display.
3. Wait 3 seconds and the display will show 10.0 h again. The TIMER OFF lamp lights and the function
is activated.
SETTING BOTH TIMER ON/OFF AT THE SAME TIME
Use this function to shut down the heat pump when you have gone to bed, and to start it before you
wake up or come home.
Carry out the following to switch off the timer after 2 hours and start it again after 10 hours.
1. Press TIMER OFF.
2. Press TIMER OFF again until 2.0 is shown in the display.
3. Press TIMER ON.
4. Press TIMER ON again until 10.0 is shown in the display.
5. Wait for 3 seconds and the temperature is shown in the display again. The TIMER ON/OFF lamp
lights and the function is activated.
TURBO
SELF
CLEAN
SLEEP
FRESH
SILENCE
TIMER
ON
TIMER
OFF
LOCK RESET
LED
FOLLOW
ME
FAN
SPEED
SWING
MODE
TEM P
ON/OF F
SWING
Start
Off
6 hours later
Set
TIMER ON
Stop
On
Set 10 hours later
TIMER
OFF
On
Stop
2 hours later
after setting
Set
Start
10 hours later
after setting
TIMER ON OFF
FP
FP
EN
EN