Grand Soleil 50’
- -
45
Air conditioning system
It has been conceived in order to install independent units in one or more rooms. This feature
makes it particularly flexible and able to meet different customer requirements. Among the different
system types and the possible solutions available in the market, please find below the description of
the CLIMMA units for the air conditioning of all cabins and the wardroom.
This system includes (see page 47 for the components location):
•
Condenser cooling water seacock with its through-hull valve, located under the galley floorboard
near the sink drain.
•
Sea water filter, installed near the pump described below, in order to protect it.
•
Circulation pump, sucking the sea water from the above-described seacock and piping it to the
two air conditioning units. This pump is installed under the floorboard, between the sofa and the
dinette table, together with draining pipes, one for each unit, which merge into the same drain to
the left of the life raft peak.
•
Air conditioning unit, installed under the seat abaft the wardroom sofa, that is to say against the
galley sink cabinet, cooling the fore cabin and the dinette. The relevant outlet and intake grilles
are located as follows:
-
an outlet grille in the fore cabin, above, towards the port hull side, near the bathroom
bulkhead;
-
two outlet grilles in the surface behind the dinette sofa back;
-
an intake grille, in the vertical side of the sofa containing the air conditioning unit.
•
Air conditioning unit cooling the two aft cabins, similar to the above-described one, but with
only one battery/fan unit, installed between the engine room and the fuel tank container, that is to
say above the engine exhaust silencer. The relevant outlet and intake grilles are located as
follows:
-
an outlet grille in each aft cabin, on the bent side of the engine room bulkhead;
-
an intake grille, in the door accessing the starboard aft cabin air conditioning unit.
•
Each unit has an electrical pump for the condensation drain with its protective filter.
-
The fore unit pump is located under the dinette floorboard, near the sea water filter, and it
directly drains on the port hull side, in line with the pump.
-
The aft unit pump is located under the unit support surface and it drains through a scupper
on the port hull side, towards the stern.
•
Black electrical box with protective fuse, near every air conditioning unit.
•
Temperature adjusting and control panel for the dinette and the fore cabin, located in the surface
behind the port sofa back, near the grille towards the stern.
•
Temperature adjusting and control panel for the aft cabins, located in the starboard aft cabin, just
above the air conditioning unit door accessing.