background image

 Page: 

5/9 

 

Zodiac LITE Installation Instructions 

May 2008 

!

 Rev 1.5 

 

8-PIN CONNECTOR  

 

For wiring to a Wiegand controller or a Zodiac Door 
Control Module  

 

 
 
SET SCREW  

 

Insert from bottom of reader after mounting on 
mounting plate 

 

DIP SWITCHES

 

 

 

DIP SWITCH # 

ON OFF 

DCM MODE 

READER MODE 

2 Normal 

Security 
MODE 

High  
Security 
MODE 

3 N/A 

N/A 

4 N/A 

N/A 

 

 
DCM MODE: 

If you are connecting Zodiac Lite to ZDCM board, 

DIP switch # 1 has to be in ON position.

 

 
READER MODE: 

If you are connecting Zodiac Lite to any Access Panel (CP40, SmartLock Pro or any 26-bit access panel),  

DIP switch # 1 has to be in OFF position. 
 
NORMAL SECURITY MODE: 

By default setup 

DIP switch #2 is in ON

 position, in this case Zodiac performs a normal authentication process.

 

 
HIGH SECURITY MODE: 

In this mode Zodiac performs a high authentication process. 

 

If any changes are made at the DIP switch setting press RESET BUTTON to apply new setup. 

 
 
 
 
 
 

Содержание Zodiac LITE

Страница 1: ...Zodiac LITE INSTALLATION INSTRUCTIONS May 2008...

Страница 2: ...Rev 1 5 Table of Contents Introduction 3 Specifications 3 Zodiac Lite Reader Wiring 4 5 Zodiac Door Control Module ZDCM 6 Wiring the Zodiac Lite Stand Alone Kit 7 Wiring Lock Devices Electric Strikes...

Страница 3: ...roller Reader Output Reader Mode 26 bit or Cansec 37 bit Wiegand DCM Mode Cansec proprietary DCM Wiegand Operating Temperature 15 C to 60 C 5 F to 140 F Size 87 mm w x 144 mm h x 38 mm d 3 4 in w x 5...

Страница 4: ...reader The right LED is externally controlled by the host controller It changes from red to green when the LED line is pulled low MOUNTING PLATE Surface mount fits standard single gang electrical box...

Страница 5: ...MODE If you are connecting Zodiac Lite to ZDCM board DIP switch 1 has to be in ON position READER MODE If you are connecting Zodiac Lite to any Access Panel CP40 SmartLock Pro or any 26 bit access pa...

Страница 6: ...rical plate After wiring is complete simply screw the ZDCM into a standard single gang electrical box ZDCM CONNECTIONS D R R T E R E L A Y R E A D E R 12 VDC INPUT DOOR CONTACT REQUEST TO EXIT LOCK DE...

Страница 7: ...on Instructions May 2008 Rev 1 5 Wiring the Zodiac LITE Stand Alone Kit When you are wiring a Zodiac LITE reader to a Zodiac Door Control Module the reader must be set to DCM Mode Refer to the Wiring...

Страница 8: ...Wiring Lock Devices ELECTRIC STRIKES Powering 12 VDC electric strikes from the Zodiac Door Control Module Powering DC electric strikes from a separate external DC power supply Note Use 1N400x series d...

Страница 9: ...WIRE 12 VDC MAGLOCK MAX 2 A 12 VDC SUPPLY 12V IN GND 12V OUT COM NO NC GND 1N400x Diode ZODIAC DOOR CONTROL MODULE MAGLOCK MAX 2 A 30 VDC EXTERNAL POWER SUPPLY DC 12 VDC SUPPLY 12V IN GND 12V OUT COM...