Zodiac LITE Installation Instructions
May 2008
!
Rev 1.5
8-PIN CONNECTOR
-
For wiring to a Wiegand controller or a Zodiac Door
Control Module
SET SCREW
-
Insert from bottom of reader after mounting on
mounting plate
DIP SWITCHES
DIP SWITCH #
ON OFF
1
DCM MODE
READER MODE
2 Normal
Security
MODE
High
Security
MODE
3 N/A
N/A
4 N/A
N/A
DCM MODE:
If you are connecting Zodiac Lite to ZDCM board,
DIP switch # 1 has to be in ON position.
READER MODE:
If you are connecting Zodiac Lite to any Access Panel (CP40, SmartLock Pro or any 26-bit access panel),
DIP switch # 1 has to be in OFF position.
NORMAL SECURITY MODE:
By default setup
DIP switch #2 is in ON
position, in this case Zodiac performs a normal authentication process.
HIGH SECURITY MODE:
In this mode Zodiac performs a high authentication process.
If any changes are made at the DIP switch setting press RESET BUTTON to apply new setup.