background image

 Page: 

3/9 

 

Zodiac LITE Installation Instructions 

May 2008 

!

 Rev 1.5 

 

Introduction 

 

The Zodiac LITE biometric fingerprint reader allows all programming and user management to take place right at 
the reader, without having to run cables to a PC. Up to 90 user templates can be stored in the reader’s non-volatile 
memory. When used with a power supply and a door control module, this reader becomes the focal point of a 100 
per cent PC-free, stand-alone door access control system.

 

 
 
Specifications

*

 

 

ZODIAC LITE READER 

 

Power Requirements:

 ........................................................................................................................... 12 VDC, 300 mA  

Wiegand Cable:

 ................................................................................. 22 AWG, 6 conductors, Stranded, Overall Shield,  

Maximum 152 m (

500 ft

) to controller 

Reader Output:

 

 

Reader Mode:  ..................................................................................................  26-bit or Cansec 37-bit Wiegand 

 DCM 

Mode 

 

................................................................................................. 

Cansec proprietary DCM Wiegand  

Operating Temperature:

 .................................................................................................... -15°C to 60°C (5°F to 140°F)

 

Size:

  

......................................................... 

87 

mm (w) x 144 mm (h) x 38 mm (d) [3.4 in (w) x 5.7 in (h) x 1.5 in (d)]

 

Weight:

   ........................................................................................................................................................... 397 g (14 oz)

 

Housing:

 .................................................................................................................................................. High  impact  ABS 

Mounting:

 ................................................................................................................................... Single-gang electrical box 

Sensor: 

 Manufacturer: 

 

............................................................................................................................................   Nitgen 

 

Type:   ......................................................................................................................................................... Optical 

 Authentication:   ................................................................................................................................... <1  Second 

LED Indicators:

 ................................................................................................................. Bi-colour  standard (red, green) 

 

1 x authentication indicator (left) 

 

1 x externally controlled indicator (right) 

Audio Tone:

 ............................................................................................................................................... Internal  beeper 

 

ZODIAC DOOR CONTROL MODULE 

 

Power Requirements:

 ..............................................................................................................................12 VDC, 50 mA  

Operating Temperature:

 ................................................................................................. -40°C to 85°C (-40°F to 185°F)

 

Size:

  

........................................................... 

36 

mm (w) x 61 mm (h) x 10 mm (d) [1.4 in (w) x 2.4 in (h) x 0.4 in (d)]

 

Weight:

  .............................................................................................................................................................. 28 g (1 oz)

 

 

Lock Relay (on ZDCM) 

 

 

 Arrangement:

 .................................................................................................................................................  Form C 

 

Nominal Switching Capacity:

 ................................................................................................................ 2  A, 30 VDC 

 
 

 
 
 
*Specifications subject to change without notice 

Содержание Zodiac LITE

Страница 1: ...Zodiac LITE INSTALLATION INSTRUCTIONS May 2008...

Страница 2: ...Rev 1 5 Table of Contents Introduction 3 Specifications 3 Zodiac Lite Reader Wiring 4 5 Zodiac Door Control Module ZDCM 6 Wiring the Zodiac Lite Stand Alone Kit 7 Wiring Lock Devices Electric Strikes...

Страница 3: ...roller Reader Output Reader Mode 26 bit or Cansec 37 bit Wiegand DCM Mode Cansec proprietary DCM Wiegand Operating Temperature 15 C to 60 C 5 F to 140 F Size 87 mm w x 144 mm h x 38 mm d 3 4 in w x 5...

Страница 4: ...reader The right LED is externally controlled by the host controller It changes from red to green when the LED line is pulled low MOUNTING PLATE Surface mount fits standard single gang electrical box...

Страница 5: ...MODE If you are connecting Zodiac Lite to ZDCM board DIP switch 1 has to be in ON position READER MODE If you are connecting Zodiac Lite to any Access Panel CP40 SmartLock Pro or any 26 bit access pa...

Страница 6: ...rical plate After wiring is complete simply screw the ZDCM into a standard single gang electrical box ZDCM CONNECTIONS D R R T E R E L A Y R E A D E R 12 VDC INPUT DOOR CONTACT REQUEST TO EXIT LOCK DE...

Страница 7: ...on Instructions May 2008 Rev 1 5 Wiring the Zodiac LITE Stand Alone Kit When you are wiring a Zodiac LITE reader to a Zodiac Door Control Module the reader must be set to DCM Mode Refer to the Wiring...

Страница 8: ...Wiring Lock Devices ELECTRIC STRIKES Powering 12 VDC electric strikes from the Zodiac Door Control Module Powering DC electric strikes from a separate external DC power supply Note Use 1N400x series d...

Страница 9: ...WIRE 12 VDC MAGLOCK MAX 2 A 12 VDC SUPPLY 12V IN GND 12V OUT COM NO NC GND 1N400x Diode ZODIAC DOOR CONTROL MODULE MAGLOCK MAX 2 A 30 VDC EXTERNAL POWER SUPPLY DC 12 VDC SUPPLY 12V IN GND 12V OUT COM...

Отзывы: