SmartLock
®
Controller
Page 8 of 26
Installation Manual
Nov 2018 • Rev. 3.2
SmartLock Controller Layout
Important Notes
:
1.
Each controller must have a unique address.
Refer to the Controller Address Table.
2.
Exit reader must be Wiegand only. Native iButton
®
reader not supported
for exit.
3.
Before connecting readers with power ON, make sure
Reader Voltage
Selection Jumper
is set to proper voltage for reader, otherwise the reader
may be damaged.
4.
Do
NOT
connect power to any inputs on the controller.
5.
The
Door Contact Input
should be bypassed,
if not used
, by using a
jumper wire across the input or setting the switch to ignore the input.
Refer
to the Door Contact Bypass Switch Setting
.
6.
This controller utilizes “self-resetting” fuses. There are no field-serviceable
parts.
1
2
3
4
5
6
7
8
O
N
WIEGAND
DATA LED
COMMS
LED
O
F
F
O
N
8
1
+
5
V
+
1
2
V
N/O
N/C
N/O
N/O
N/C
N/C
+12 VDC
INPUT
EXIT READER
(WIEGAND)
ENTRY READER
(WIEGAND)
ENTRY READER
or
PROGRAMMING MODULE
(iBUTTON)
DOOR CONTACT
EXIT BUTTON
DOOR OPERATOR
(INPUTS)
LOCK CONTROL
DOOR OPERATOR
FORCED/HELD OPEN
(OUTPUTS)
RS-485
COMMUNICATIONS
RELAY LEDS
ADDRESS
SWITCH
READER VOLTAGE
SELECTOR
DEFAULT
(DO NOT CHANGE)
L
O
C
K
F
O
R
C
E
D
/
D
H
O
D
O
O
R
O
P
E
R
.
FIRMWARE CHIP