D:
DIP SWITCH
= Default position: Switch 1, 2, and 3
OFF
; switch 4
ON
Switch 1
OFF
= Common Mode.
Buttons I and II
on the SmartFob transmitter will send data via
AD0 and AD1 and activate relay 1
if relay activation is on
ON
= Split Mode.
Button I
will send data via AD0 and AD1 and activate relay 1*
Button II
will send data via BD0 and BD1 and activate relay 2*
Switch 2
OFF
= A single valid data bundle is received and then Wiegand data is
sent to the access controller.
See the
DIP Switch 2
note
below.
ON
= Receiver will read and validate and compare two successive data
bundles. If they are the same, then Wiegand data is sent to the
access controller.
See the
DIP Switch 2
note
below.
Switch 3
OFF
= 37-bit Cansec propriety Wiegand.
ON
= 26-bit standard Wiegand.
Switch 4
OFF
= Relay activation off.
ON
= Relay activation on.
DIP Switch 2:
In extremely noisy areas, some random Wiegand data may
pass the decoding tests and produce an invalid number to the access control
panel. Enabling DIP switch 2 will eliminate the problem.
Smartfob Receiver MN: SFR2RXB
Page 10 of 17
Installation Manual
July 2008 • Rev. 1.0