H1000 Elevator Control
Page 9 of 20
Installation Guide
October 2015 • Rev. 1.7
Edit->Elevator Sets. Select 48 Floors.
64 FLOOR ELEVATOR SYSTEM
This configuration is used when connecting to an elevator of up to 64 floors. This consists of
four
H1000 control panels, designated as a master panel and three slave panels.
Master
Slave 1
Slave 3
Slave 2
Master Panel: Controls floor 1 to 16
Slave 1 Panel: Controls floor 17 to 32
Slave Panel 2: Controls floor 33 to 48
Master and slave RS485 communication wires
RS485 Communication wires to host computer using Cansec
communication line driver, e.g. CLAUSB, Canlan or Air-485
Slave 3 Panel: Controls floor 49 to 64