– 22 –
?I
Check whether or not there is a current HD-SDI input
Format: “?I”
Status report: “1”: There is an input
“0”: There is no input
VB
Specify the video bit rate for encoding
Format:
“(Integer) VB”
Specify the bit rate value in units of 400 bps
Status report: Completion message (“R”)
E06: Command argument error (when a bit
rate is not specified)
The video bit rate specified with this command is set during
encoding when it is possible to specify the video bit rate with
the DIP switch settings (SW6=SW7=SW8=ON).
When the bit rate was set during encode operation, encoding
is restarted if SW6=SW7=SW8=ON.
When the bit rate was set during decode operation, the set
value is enabled from the next encode operation.
?B
Check the video bit rate that was specified during encoding
Format: “?B”
Status report: “(Bit rate value in units of 400 bps)”
Returns the bit rate value that is used when it is possible to
specify the video bit rate with the DIP switch settings
(SW6=ON SW7=ON SW8=ON).