58
Detail Settings
Log
"Recipient Mail Address"
Specifies the log mail recipient.
"Syslog Server Host"
Sets the Syslog server.
"Maximum Log File Number"
Sets the maximum number of log files
saved as back-up files. Enter an integer
between 0 and 10. The maximum number
is 10.
"Maximum Log File Size (K bytes)"
Sets the maximum log file size. Enter an
integer between 16 and 1024. The
maximum size is 1024 KB.
"Log mail collection time (min.)"
Log messages containing errors,
warnings and other information are
collected for a set period beginning from
the first log entry. This setting specifies
that collection period. Enter an integer
between 0 and 60. The maximum time is
60 minutes.
"Handling of Error/Warning/Information"
Tick the "File" option to save log
messages to files.
Tick the "Forward" option to send the
log messages to a Syslog server host.
Tick the "Mail" option to send the log
messages by email.
c
Note
●
The log message will be stored on the flash memory card (sold separately).
Even if settings are made for this page, this function will not operate unless a
flash memory card is inserted into the slot on the VB101.
●
See Chapter 7 (
→
P.146 ) for log message details.
●
The log message for external device input (sensor, etc.) is A023(
→
P.148). If the "Log mail
collection time" has been set, this message will be sent after a specified waiting time.
e
Tip
●
Log files will be created in the /card/logs directory (a flash memory card is required to save log messages
in a file). The most recent log file will be saved as "log". The log file size is specified in "Maximum Log
File Size" and if the log file exceeds the specified size, back-up files named "log.0..." are created.
●
Only the number of back-up log files that are specified in "Maximum Log File Number (N+1)" will
remain. These will be listed in the order, "log.0, log.1,..., log.N". For example, if "Maximum Log File
Number" is set to 10, files named "log.0, log.1,..., log.9" will be created in the same directory. The file
named "log.0" is the most recent back-up file (the most recent log file is listed as "log").
●
Log files will be overwritten in order after the number of files specified in "Maximum Log File
Number" have been created.
Click the [OK] button to change the settings. To discard the changes, click the
[Cancel] button. This returns you to the settings title page.