Canon
varioPRINT 6000 TITAN Series Customer Expectations Document
Revision 4
varioPRINT 6000 TITAN Series Customer Expectations Document
Page 46
6.14 BGB3202 Perfect Binder
Item
Specifications
Description
Inline glue binder designed for on-demand publishing. Delivers a strong
bind with rapid cooling glue in conjunction with milling and notching of
the spine.
Binding Method
Hot glue at spine
Book Thickness
Approximately 0.04" to 2.4" (1 mm to 60 mm)
Equivalent to approximately 1,200 pages maximum of (20 lb bond
(80 g/m
2
)) media
Paper Size (W x L)
Minimum (Online):
8” x 8” (203 mm x 203 mm)
Minimum (Hand Fed): 3.9” x 3.9” (100 mm x 100 mm)
Maximum (Online):
13.8” x 12.6” (350 mm x 320 mm)
Maximum (Hand Fed): 15.2” x 12.6” (385 mm x 320 mm)
Paper Weight
Body:
16 to 43 lb bond (60 to 163 g/m
2
)
Cover:
20 lb bond to 110 lb cover (80 to 300 g/m
2
)
Cover Size (W x L)
Minimum (Online):
8” x 16” (203 mm x 407 mm)
Minimum (Hand Fed): 3.9” x 7.9” (100 mm x 201 mm)
Maximum (Online):
13.8” x 25.2” (350 mm x 640 mm)
Maximum (Hand Fed): 15.0” x 29.5” (385 mm x 750 mm)
Cover Stack Height
Approximately 3.15” (80 mm)
Cover Type
Coated paper and card stock with windows and transparent fronts
Throughput
Depends on the printer.
Offline Maximum: Approximately 290 books per hour
Warm Up Time
Approximately 45 minutes
Noise at Operator Position
Approximately 76 dB
Power Source
Three phase 208 V, 60 Hz, 12 A
Power
Consumption
BGB3202
Standby:
Approximately 1,500 W
Operation:
Approximately 4,000 W
Maximum:
Approximately 5,500 W
Compiler
Maximum:
Approximately 500 W
Recommended Room Volume
Approximately 3,336 ft
3
(23 ft x 14.8 ft x 9.8 ft)
(95 m
3
(7 m x 4.5 m x 3 m))
Recommended Room
Ventilation
Minimum:
Approximately 47.5 m
3
/hr
Natural Ventilation: Approximately 1,678 ft
3
/hr
Dust Concentration
Approximately 1.25 x 10
-4
g/ft
3
at continuous operation
(TLV for nuisance dust = 44 x 10
-4
g/ft
3
(10 mg/m
3
))
Dimensions (H x W x D)
59” x 113” x 94.9” (1,500 mm x 2,870 mm x 2,410 mm)
Weight
Approximately 2,713 lb (1,231 kg)
20 Includes the Binder Unit, Compiler, and Output Unit. The dimensions are when the perfect binder is
assembled.
52 Depends on the media type.
53 To avoid higher sound pressure levels, the machine should be installed in a room that is within the minimum
room volume.
54 For heat evacuation at continuous binding, extra ventilation may be necessary.