Commands
NOSIG
Mode
Control Setting
Reference
Function
Display screen setting when no signal
Parameter
ID
Parameter Meaning
BLACK
Black screen
BLUE
Blue screen
LOGO
User screen
The RANGE command can be used to obtain the parameter range that can be set at that time.
Response
An 'i:OK' is returned after setting is successful.
Description
This sets the display screen when no image signals are input.
(1) This command is identical to the No signal screen function under the User screen settings in the Display
settings menu.
(2) Before a user screen (LOGO) is designated, the user image needs to be registered beforehand. (Otherwise, a
“e:1002 NO_LOGO_CAPTURED” is returned.)
(3) The GET command can be used to obtain the current display screen at no signal.
Example
Setting
> NOSIG=BLUE
This sets the “Blue” screen when no signals are input.
< i:Ok
Reference
> GET NOSIG or ?NOSIG
This retrieves the screen when no signals are input.
<
g:NOSIG=LOGO
Obtain settable parameters
> RANGE NOSIG
< r:NOSIG=I,BLACK,BLUE,LOGO
※
Commands are indicated by “>”, and responses are indicated by “<”
Supported Command States
Power supply
Input
Mode
OFF
ON
PM
D-RGB
A-RGB1 A-RGB2
Comp
Video
S-Video
None
Remote
Local
×
○
×
○
○
○
○
○
○
○
○
×
※
If a state is not supported, “INVALID_MODE” or “NOT_POWER_SUPPLIED” is returned with the Err response.
※
When the power supply state is in the process of switching, an “i:BUSY” reply may be sent.