Commands
PJON
Mode
Control Setting
Reference
Function
Display screen setting at startup
Parameter
ID
Parameter Meaning
CANON
Canon logo
SKIP
No display
LOGO
User screen
The RANGE command can be used to obtain the parameter range that can be set at that time.
Response
An 'i:OK' is returned after setting is successful.
Description
This sets the screen displayed at startup.
(1) This command is identical to the Logo position function under User screen settings in the Display settings
menu.
(2) Before a user screen (LOGO) is designated, the user image needs to be registered beforehand. (Otherwise, a
“e:1002 NO_LOGO_CAPTURED” is returned.)
(3) The GET command can be used to obtain the current screen displayed at startup.
Example
Setting
> PJON=CANON
This sets the startup screen to “Canon logo”.
< i:OK
Reference
> GET PJON or ?PJON
This retrieves the startup screen.
<
g:PJON=SKIP
Obtain settable parameters
> RANGE PJON
< r:PJON=I,CANON,SKIP,LOGO
※
Commands are indicated by “>”, and responses are indicated by “<”
Supported Command States
Power supply
Input
Mode
OFF
ON
PM
D-RGB
A-RGB1 A-RGB2
Comp
Video
S-Video
None
Remote
Local
×
○
×
○
○
○
○
○
○
○
○
×
※
If a state is not supported, “INVALID_MODE” or “NOT_POWER_SUPPLIED” is returned with the Err response.
※
When the power supply state is in the process of switching, an “i:BUSY” reply may be sent.