Service Mode
Service Mode
5-17
5-17
Service Mode > Test Mode (TEST) > MODEM Test > Frequency Test (FREQ)
Service Mode > Test Mode (TEST) > MODEM Test > Frequency Test (FREQ)
MODEM Test
■
Relay Test (RELAY-1)
Use it to see if the individual relays on the NCU board go on and off as expected.
<1/1>
<MODEM>
<READY>
Report
Sssw Menu Num Ncu Type IPFAX Print Clear
Test
CML
P
S
H
D
R
<RELAY-1>
OFF
OFF
OFF
OFF
OFF
OFF
OK
●
Using Test Mode
1) From the relays indicated on the screen, select the one you want to test; then, turn it off
or on using the Up/Down key. (Some of the relays may not actually exist on the NCU
board.)
F-5-15
■
Frequency Test (FREQ)
Of the items indicated below, press one; in response, the DC circuit will be closed and the
selected frequency will be transmitted using the tone transmission function of the modem.
You can also monitor the transmission signal by listening to the sound generated by the
speaker. To stop the operation and end test mode, press the key.
<1/1>
<READY>
Report
Sssw Menu Num Ncu Type IPFAX Print Clear
Test
<FREQ>
<MODEM>
OK
RBT
462Hz
1100Hz
1300Hz
1500Hz
1650Hz
1850Hz
2100Hz
Caution:
'RBT' is not currently supported.
F-5-16
Содержание Super G3 FAX Board-AR1
Страница 6: ... Notes Before it Works Serving Safety Precautions ...
Страница 8: ...1 1 Product Outline Product Outline Product Outline Specifications ...
Страница 10: ...2 2 Technology Technology Technology Basic Construction Controls ...
Страница 16: ...4 4 Error Code Error Code Error Code Overview User Error Code Service Error Code ...