CANON SmartBase PC1200s/iR1200s REV. 0 DEC. 2001
7-9
CHAPTER 7 TROUBLESHOOTING
1.3.3 Adjusting the Mechanical Systems
1.3.3.1 Removing the Skew
Make a copy of the test sheet using the ADF in Direct, and make sure that the skew is as
indicated (T07-103-01). (See 1.2.2 of Chapter 7.)
Copy of the test sheet
a
b
(feeding direction)
F07-103-01
T07-103-01
1) Open the ADF.
2) Loosen the 3 screws [1], and move the left hinge up and down so that the skew will be
as indicated by referring to the index graduated at 1-mm intervals.
[1]
F07-103-02
b-a
Dimension (using A4)
0 ± 1.3 mm
Dimension (using LTR)
0 ± 1.3 mm
Содержание SmartBase iR1200s
Страница 16: ......
Страница 18: ......
Страница 44: ......
Страница 139: ...COPYRIGHT 2001 CANON INC 2000 2000 2000 2000 CANON SmartBase PC1200s iR1200s REV 0 DEC 2001 CHAPTER 3 INSTALLATION ...
Страница 140: ......
Страница 156: ......
Страница 157: ...COPYRIGHT 2001 CANON INC 2000 2000 2000 2000 CANON SmartBase PC1200s iR1200s REV 0 DEC 2001 CHAPTER 4 OPERATION ...
Страница 158: ......
Страница 203: ...COPYRIGHT 2001 CANON INC 2000 2000 2000 2000 CANON SmartBase PC1200s iR1200s REV 0 DEC 2001 CHAPTER 5 MECHANICAL SYSTEM ...
Страница 204: ......
Страница 270: ......
Страница 272: ......
Страница 281: ...COPYRIGHT 2001 CANON INC 2000 2000 2000 2000 CANON SmartBase PC1200s iR1200s REV 0 DEC 2001 CHAPTER 7 TROUBLESHOOTING ...
Страница 282: ......
Страница 390: ......
Страница 391: ...COPYRIGHT 2001 CANON INC 2000 2000 2000 2000 CANON SmartBase PC1200s iR1200s REV 0 DEC 2001 APPENDIX ...
Страница 392: ......
Страница 396: ...APPENDIX A 4 COPYRIGHT 2001 CANON INC 2000 2000 2000 2000 CANON SmartBase PC1200s iR1200s REV 0 DEC 2001 Blank page ...
Страница 400: ......