(10/37)
Error
code
TX /
RX
Meaning
Solution
(parts that are likely to be faulty)
##762 TX
After transmitting PPS-EOM in ECM transmission,
DCN has been received.
- Try a higher transmission level.
##763 TX
After transmitting PPS-EOM in ECM transmission,
re-transmission of the procedure signal has been
attempted the number of specified times but failed,
or T5 time-over (60 sec.) has occurred.
- Increase the period of time of the T5
time-over.
##764 TX
After transmitting PPS-EOM in ECM transmission,
re-transmission of the procedure signal has been
attempted the number of specified times but failed.
- Try a higher transmission level.
- Increase the transmission level of the
receiving machine.
##765 TX
After transmitting PPS-EOP in ECM transmission,
no significant signal has been received, and
re-transmission of the procedure signal has been
attempted the number of specified times but failed.
- Try a higher transmission level.
- Increase the transmission level of the
receiving machine.
##767 TX
After transmitting PPS-EOP in ECM transmission,
DCN has been received.
- Try a higher transmission level.
##768 TX
After transmitting PPS-EOP in ECM transmission,
re-transmission of the procedure signal has been
attempted the number of specified times but failed,
or T5 time-over (60 sec.) has occurred.
- Increase the period of time of the T5
time-over.
##769 TX
After transmitting PPS-EOP in ECM transmission,
re-transmission of the procedure signal has been
attempted the number of specified times but failed.
- Try a higher transmission level.
- Increase the transmission level of the
receiving machine.
##770 TX
After transmitting EOR-NULL in ECM transmission,
no significant signal has been received, and
re-transmission of the procedure signal has been
attempted the number of specified times but failed.
- Try a higher transmission level.
- Increase the transmission level of the
receiving machine.
##772 TX
After transmitting EOR-NULL in ECM transmission,
DCN has been received.
- Try a higher transmission level.
##773 TX
After transmitting EOR-NULL in ECM transmission,
re-transmission of the procedure signal has been
attempted the number of specified times but failed,
or T5 time-over (60 sec.) has occurred.
- Increase the period of time of the T5
time-over.
##774 TX
After transmitting EOR-NULL in ECM transmission,
ERR has been received.
- Try a higher transmission level.
##775 TX
After transmitting EOR-MPS in ECM transmission,
no significant signal has been received, and
re-transmission of the procedure signal has been
attempted the number of specified times but failed.
- Try a higher transmission level.
##777 TX
After transmitting EOR-MPS in ECM transmission,
DCN has been received.
- Try a higher transmission level.
##778 TX
After transmitting EOR-MPS in ECM transmission,
re-transmission of the procedure signal has been
attempted the number of specified times but failed,
or T5 time-over (60 sec.) has occurred.
- Increase the period of time of the T5
time-over.
##779 TX
After transmitting EOR-MPS in ECM transmission,
ERR has been received.
- Try a higher transmission level.
Содержание PIXMA MX340 Series
Страница 22: ... 21 37 PTT parameter print sample for the MX350 US model ...
Страница 30: ... 29 37 3 5 Grease application ...
Страница 32: ... 31 37 4 EXTERNAL VIEW PARTS LIST 4 1 External View Fig 1 ...
Страница 33: ... 32 37 Fig 2 1 For the MX340 MX347 MX348 only 2 For the MX350 MX357 MX358 only ...
Страница 34: ... 33 37 Fig 3 ...
Страница 35: ... 34 37 Fig 4 2 For the MX350 only 3 Ink absorbers to be replaced in the partial replacement ...