
Time(s)
*1
Ink absorber
0 times
Main ink absorber (0%)
1 time
Platen ink absorber (0%)
2 times
Both the main and platen ink absorbers (0%)
3 times or more Press the ON/OFF button to return to the ink amount resetting mode.
3) Press the ON/OFF button to specify the ink absorber whose value should be reset to 0%.
4) After the ink absorber counter is reset, the counter value is printed automatically.
("D=000.0 Ps=000.0" is printed at the top left of the paper.)
*1
: According to the number of times the Stop/Reset button is pressed, the LED lights as follows:
- Odd number of times: Alarm LED lights
- Even number of times: ON/OFF LED lights
<Destination settings>
In the destination settings mode, press the Stop/Reset button the specified number of time(s) according to
the destination listed in the table below, and press the ON/OFF button.
Time(s)
LED indication
Destination
0 times
Green (Power)
No change of the destination
1 time
Orange (Alarm)
Japan
2 times
Green (Power)
Korea
3 times
Orange (Alarm)
US
4 times
Green (Power)
Europe
5 times
Orange (Alarm)
Australia
6 times
Green (Power)
Asia
7 times
Orange (Alarm)
China
8 times
Green (Power)
Taiwan
9 times
Orange (Alarm)
Latin America
10 times
Green (Power)
Brazil
11 times
Orange (Alarm)
Canada
12 times or more
Green (Power)
Return to the destination selection
Note: After setting the destination, confirm the model name and destination in service test print or EEPROM
information print.
(13/32)