The microprocessor on the machine’s DC controller PCB is equipped with a self diagnostic
mechanism that checks the condition of the machine (particularly, sensors) and indicates an error
code in the count/ratio indicator on the control panel upon detection of a fault.
In the case of ‘E001’, ‘E0’ and ‘01’ are flashed alternately.
Code
Cause
Description
‘E000’, ‘E001’, ‘E002’, or ‘E003’ has
occurred.
• The thermistor (TH1) is faulty.
• The fixing heater (H1) is faulty.
• The thermal fuse (FU2) has blown.
• The DC controller PCB is faulty.
• The composite power supply PCB is
faulty.
• The thermistor (TH1) is faulty.
• The DC controller PCB is faulty.
• The composite power supply PCB is
faulty.
• The thermistor (TH1) is faulty.
• The fixing heater (H1) is faulty.
• The thermal fuse (FU2) has blown.
• The DC controller PCB is faulty.
• The composite power supply PCB is
faulty.
• The thermistor (TH1) is faulty.
• The fixing heater (H1) is faulty.
• The thermal fuse (FU2) has blown.
• The DC controller PCB is faulty.
• The composite power supply PCB is
faulty.
The power switch is turned off and then
on immediately after an error (‘E000’,
‘E001’, ‘E002’, ‘E003’) has occurred.
• The temperature detected by the
thermistor (TH1) does not reach 65°C
1.5 sec after the Copy Start key has
been pressed.
• The temperature detected by the
thermistor (TH1) does not reach 150°C
4 sec after the Copy Start key has been
pressed.
• The temperature detected by the
thermistor (TH1) exceeds 230°C.
• The temperature detected by the
thermistor (TH1) exceeds by 30°C or
more.
• The temperature detected by the
thermistor (TH1) registers an increase
of 100°C or more within 1 sec.
• The temperature detected by the
thermistor (TH1) registers an increase
of 40°C or more after it has reached
100°C during standby.
• E0 detection signal (E0_DT) is de-
tected twice or more in succession.
• The temperature detected by the
thermistor (TH1) has exeeded 150°C
during copy operation and maximum
power is applied for 10 to 14 sec
thereafter.
• The temperature detected by the
thermistor (TH1) drops to and remains
150°C or lower after it has reached
160°C.
Содержание PC920
Страница 6: ...COPYRIGHT 1999 CANON INC CANON PC800s 900s REV 0 AUG 1999 PRINTED IN JAPAN IMPRIME AU JAPON i v ...
Страница 12: ......
Страница 34: ......
Страница 36: ......
Страница 48: ......
Страница 50: ......
Страница 92: ......
Страница 94: ......
Страница 122: ......
Страница 124: ......
Страница 162: ......
Страница 164: ......
Страница 180: ......
Страница 206: ......
Страница 240: ......
Страница 242: ......
Страница 256: ......
Страница 263: ......
Страница 265: ......
Страница 355: ......
Страница 359: ...A 4 COPYRIGHT 1999 CANON INC CANON PC800s 900s REV 0 AUG 1999 PRINTED IN JAPAN IMPRIME AU JAPON ...
Страница 373: ...A 18 COPYRIGHT 1999 CANON INC CANON PC800s 900s REV 0 AUG 1999 PRINTED IN JAPAN IMPRIME AU JAPON ...
Страница 383: ......
Страница 393: ...0899AB2 135 1 PRINTED IN JAPAN IMPRIME AU JAPON This pubication is printed on 70 reprocessed paper ...