-7-
WARNING:
- Allow a projector to cool, for at least 45 minutes before you open Lamp
Cover. The inside of a projector can become very hot.
- For continued safety, replace with a lamp assembly of the same type.
- Do not drop a lamp assembly or touch a glass bulb! The glass can
shatter and may cause injury.
Procedure
1
Turn off the projector and disconnect the AC plug. Allow the projector to
cool at least for 45 minutes.
2
Remove 1 screw and remove the lamp cover.
3
Loosen 2 screws and pull out the lamp assembly by grasping the handle.
4
Replace the lamp assembly securely and tighten 2 screws.
5
Close the lamp cover and tighten 1 screw.
6
Connect the AC Power Cord to the projector and turn on the projector.
Note:
- Do not reset the Lamp Replace Counter, except after lamp is replaced.
- The projector can not be turned-on with lamp cover removed, because
when the lamp cover is removed, the lamp cover switch is also released
to switch off the mains power for safety.
7
Reset the Lamp Replace Counter, see below explanation
.
■
Lamp Replacement
1
Turn the projector on, press the
MENU
button and the
On-Screen Menu will appear.
Press the
POINT
LEFT/RIGHT
buttons to move the red frame pointer to
the Setting Menu icon.
2
Press the
POINT DOWN
button to move the red
frame pointer to the Lamp counter reset item and then
press the
OK
button. The message “Lamp replace
counter reset?” is displayed. Move the pointer to [Yes]
and then press the
OK
button.
3
Another confirmation dialog box appears and select
[Yes] to reset Lamp Replace Counter .
Please refer to the owners manual for further informa-
tion.
Recommendation
Should the air filter become clogged with dust particles,
it will reduce the cooling fan’s effectiveness and may
result in internal heat build up and short lamp life. We
recommend cleaning the air filter after the projection
lamp is replaced.
Refer to “Air Filter Cleaning”.
The LAMP REPLACE indicator will light yellow when
the total lamp used time reaches 2,500 hours. This is
to indicate that lamp replacement is required.
The total lamp used time is calculated by using the
below expression;
Total lamp used time =
T
eco
+
T
norma
l
(1+1/4)
T
eco
: used time in the Silent mode
T
normal
: used time in the Normal and Auto mode
You can check the lamp replace counter following to
below procedure.
1
Press and hold the
POWER
button on the projector or
the remote control unit for more than 20 seconds.
2
The projector used time and lamp used time will be
displayed on the screen briefly.
Lamp cover
Counter
Projector
Lamp
Normal
Eco
Total
130H
24H
100H
130H
Total lamp used time
ORDER REPLACEMENT LAMP
Type No.
Service Parts No.
LV-LP23
610 317 7038
How to reset Lamp Replace Counter
How to check Lamp used time
Screws
Handle
Lamp Assembly
Screw
Projector used time
* Following information differs from the model LV-S3;
- the replacement lamp number, SET --> OK button.
Содержание LV-S4
Страница 1: ...Multimedia Projector SERVICE MANUAL Original Version FILE NO Model No LV S4 ...
Страница 49: ... 49 BA9743AFV DC DC Converter IC371 IC Block Diagrams BA7078AF Sync Detector IC5301 ...
Страница 50: ... 50 IC Block Diagrams LM4865 Audio Amplifier IC5003 PW168A Scaler Main CPU IC301 ...
Страница 51: ... 51 VPC3230D Video Decoder IC101 IC Block Diagrams TA1370FG Sync Separator Frequency Counter IC5302 ...
Страница 52: ...SERVICE MANUAL LV S4U LV S4E ...