VI. MALFUNCTION STATUS TROUBLESHOOTING
If the factor of the malfunction is identified as “malfunction status troubleshooting” by the mal-
function diagnosis flowchart (Figure 4-1-1), execute the followings and mend the malfunction.
VI-1.
"10.1 ERROR FUSER CALL FOR SERVICE"
Fixing unit failure (abnormal low temperature)
"10.2 ERROR FUSER CALL FOR SERVICE"
Fixing unit failure (abnormal Warm-up)
<Possible causes>
1. The rated voltage of the fixing unit installed in the printer differs from the line voltage.
Action:
Replace the fixing unit.
2. The thermistor is dirty.
Action:
If the thermistor contact area of the upper fixing roller is dirty, clean it.
3. The thermistor is not installed correctly.
Action:
If the thermistor is not evenly contacting the upper fixing roller, re-install the ther-
mistor correctly.
4. The thermistor wire is broken.
Action:
Turn the power OFF and remove the fixing unit. Measure the resistance between
the fixing unit connector J50B-5 (FSRTH) and J50B-4 (GNDTH). If the resistance
is not between about 190k
Ω
and 290k
Ω
(room temperature of 25°C), check the
wiring from connector J222 on the DC controller PCB to the thermistor. If it is nor-
mal, replace the thermistor.
5. The main heater wire is broken.
Action:
Remove the fixing unit. If there is no continuity between the fixing unit connector
J50-3 (FSRN1: the upper right terminal of the left connector) and J51-5 (FSRN2: the
upper right terminal of the right connector), replace the main heater.
6. The sub heater wire is broken.
Action:
Remove the fixing unit. If there is no continuity between the fixing unit connector
J50-4 (FSRL1: the lower right terminal of the left connector) and J51-6 (FSRL2: the
lower right terminal of the right connector), replace the sub heater.
7. The thermoswitch is open.
Action:
Remove the fixing unit and wiring cover. If there is no continuity between ther-
moswitch terminals, replace the thermoswitch.
8. The fixing unit drive circuit is defective.
Action:
Replace the power supply unit.
9. The DC controller PCB is defective.
Action:
Replace the DC controller PCB.
4 - 21
CHAPTER 4
Содержание LBP-3260
Страница 8: ......
Страница 10: ......
Страница 12: ...This page intentionally left blank 1 2 CHAPTER 1 ...
Страница 27: ...Figure 1 5 7 1 17 CHAPTER 1 ...
Страница 36: ...This page intentionally left blank 1 26 CHAPTER 1 ...
Страница 38: ......
Страница 40: ......
Страница 55: ...2 15 CHAPTER 2 ...
Страница 71: ...This page intentionally left blank 2 31 CHAPTER 2 ...
Страница 104: ......
Страница 108: ...2 68 CHAPTER 2 ...
Страница 110: ......
Страница 160: ......
Страница 194: ...This page intentionally left blank 4 34 CHAPTER 4 ...
Страница 209: ...Figure 4 9 2 4 49 CHAPTER 4 J56 J51 J50 J54 J55 J19 J10 J24 J204 J213 J214 J222 J1302 J1304 J1303 J1301 J102 J217 ...
Страница 210: ...4 50 CHAPTER 4 ...
Страница 211: ...APPENDIX I GENERAL TIMING CHART A 1 II GENERAL CIRCUIT DIAGRAM A 3 III LIST OF SIGNALS A 5 IV MESSAGES TABLE A 11 ...
Страница 212: ......
Страница 214: ......
Страница 222: ...A 10 APPENDIX This page intentionally left blank ...
Страница 234: ...PRINTED IN JAPAN IMPRIME AU JAPON 0199AT0 70 CANON INC The printing paper contains 70 waste paper ...