2-10
2-10
2
2
Technology
Technology
b. Priority on the front original presence
As a result of main scanning direction measurement, if the original absence is detected at
the rear while the original presence is detected at the front, a priority is given to the result of
original presence at the front.
Point of detection 1
Point of detection 2
Point of detection 4
Point of detection 3
Point of detection 5
Scanner unit
original detection position
B5
Original
size
sensor1
Original detection position Result
Identi
fi
ed size
1
Y
Y
2
-
Y
3
-
Y
4
Y
Y
5
-
-
Judgment
B5
* Signal change with DADF Open to Close
Change: -
Others: Y
Detection operation
Following is the overview of operation for original size detection (AB type).
1) Wait status
Scanner unit: shading position
LED lamp unit: OFF
Original size sensor: OFF
Original detection position
Scanner unit
Original size
sensor 1
Reader unit
DADF
Copyboard
glass
Point of detection 1
Point of detection 2
Point of detection 3
Point of detection 4
Point of detection 5
DADF open/closed sensor 2
DADF open/closed sensor 1
2) DADF opened (The angle of DADF is 25 degree or more).
Scanner unit: It moves to the original detection position (20mm from the original push-on
position)
LED lamp unit: OFF
Original size sensor: OFF
■
Содержание L1
Страница 4: ...BLANK PAGE ...
Страница 10: ...BLANK PAGE ...
Страница 11: ...2 2 2 Technology Technology Technology Basic configuration Controls ...
Страница 31: ...3 3 3 Periodic Service Periodic Service Periodic Servicing Periodic Servicing List ...
Страница 41: ...5 5 5 Adjustmnet Adjustmnet Adjustments Overview Adjustment Method ...
Страница 49: ...6 6 6 Installation Installation Installation Color Image Reader L1 ...
Страница 78: ...Service Tools General Circuit Diagram Appendix Appendix Appendix ...