background image

2B996-016JA

22

( 2 )  GAIN (Video gain)

When shooting in dark locations, if the image is dark even if the lens iris is open, change the gain (video gain) to get 
the proper video level.

① 

MANU (Manual gain)
Gain adjustment is performed on the GAIN menu. The adjustment range is from 0dB to 18dB in 1dB steps.

② 

OFF
Gain is fixed at 0dB.

Move the “ ” to MODE, push the [DATA UP], [DATA DOWN], and select one of the two modes between MANU and OFF.

(2�1)  Changing the setting in GAIN

MODE

MANU

MANU

0dB

GAIN

• Gain mode   MANU, OFF
• Manual gain adjustment   0 dB to 18 dB (1 dB step)

Move up down 

by pushing 

MENU UP, DOWN

Select the desired 

value by pushing 

DATA UP, DOWN

(a) Changing the gain in MANU mode

① 

Move the “ ” to MANU by pushing [MENU UP], [MENU DOWN] buttons.

② 

Adjust the manual gain by pushing [DATA UP], [DATA DOWN] buttons.

Содержание JCT-TF5G

Страница 1: ... JCT TF5G INSTRUCTION MANUAL This manual is made from recycled paper For Customer Use Enter below the Serial No which is located on the bottom of the cabinet Retain this information for future ref erence Model No JCT TF5G Serial No ...

Страница 2: ...5 7 2 Menus 15 1 SHUTTER Electronic shutter 16 1 1 Changing the setting in MANU mode 17 1 2 Changing the setting in SS synchro scan mode 18 1 3 Changing the setting in E TRG mode 19 1 3 1 Changing the setting in 1P SR mode 19 1 3 2 Changing the setting in PW SR mode 20 1 3 3 Changing the setting in RR mode 21 1 4 Changing each setting in AUTO mode 21 2 GAIN Video gain 22 2 1 Changing the setting i...

Страница 3: ... 27 8 Returning to factory settings 28 7 3 Synchro Scan Operation 28 1 Setting by 1H 28 2 Setting by the frame 28 7 4 E TRG External trigger 29 1 1P SR 1 Pulse Trigger SYNC RESET 29 2 PW SR Pulse width trigger SYNC RESET 30 3 RR Reset restart 31 7 5 Partial Scanning 32 7 6 External Sync 33 1 External sync signal polarity 33 2 External sync frequency range 33 3 Using the unit with external sync sig...

Страница 4: ...sonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in whic...

Страница 5: ...t this product may not be treated as household waste By ensuring this product is disposed of correctly you will help prevent potential negative consequences for the environment and human health which could other wise be caused by inappropriate waste handling of this product For more detailed information about the take back and recycling of this product please contact your supplier where you purcha...

Страница 6: ...om dropping invasion of foreign objects etc may result in fire and or electric shock Immediately disconnect the power source and contact your dealer Avoid installing in a shower room or a bathroom This may result in fire and or electric shock Do not operate in places where the product may get wet This may result in fire and or electric shock Do not repair disassemble and or modify by yourself This...

Страница 7: ...en tional or accidental use under extreme operating conditions 2 Malfunction or non function resulting in indirect additional or consequential damages including but not limited to loss of expected income and suspension of business activities 3 Incorrect use not in compliance with instructions in this instruction manual 4 Malfunctions resulting from misconnection to other equipment 5 Repairs or mod...

Страница 8: ...product is not designed for any critical applications Critical applications means life support systems exhaust or smoke extraction applications medical applications commercial aviation mass transit applications military applications homeland security applications nuclear facilities or systems or any other applications where product failure could lead to injury to persons or loss of life or catastr...

Страница 9: ...ne benzene or paint thinner Places subject to strong vibration This may result in fire and or electric shock Places containing chemicals such as pesticides rubber or vinyl products for extended periods of time This may damage coating and printed letter This product is for indoor use only This may result in fire and or electric shock Do not shoot intense light If a strong light is imaged vertical s...

Страница 10: ...ton Select the function to be confirmed or changed on the menu MENU DOWN button Select the function to be confirmed or changed on the menu DATA UP AWB button Changes the value of the function selected by the MENU UP DOWN button Also used when using AWB DATA DOWN button Changes the value of the function selected by the MENU UP DOWN button DIGITAL terminal 8 bit RGB digital signal and sync signals a...

Страница 11: ...ge DC12V 10 Current rating More than 830 mA Ripple voltage Less than 50 mV p p Connector HR10A 7P 4S by HIROSE electronics Co Ltd Pins 1 2 12V Pins 3 4 GND For DC power supply connecting to DC IN 12V terminal use class II DC power supply approved accord ing to EN60950 1 in Europe or use UL listed and or CSA approved ungrounded type AC adaptor with LPS and the specifications described below in U S ...

Страница 12: ...u is displayed press the DISP button to disable the character display on the menu Shoot a known white object that fills the screen and push DATA UP button for approx 1 second The character AWB blinks on the screen when the AWB starts The character AWB stops blinking when the AWB finishes and the result is displayed for approx 1 second Result displayed Meaning AWB OK Automatic white balance adjustm...

Страница 13: ...he item 7 2 2 2 1 a Changing the gain in MANU mode OFF Gain is fixed at 0 dB 5 3 Shading Correction Due to the lens used or the environmental condition vertical color shading may occur at the top and bottom of the screen and at the corners In this case the shading correction can decrease the color shading For the shading cor rection of the unit MANU Manual shading correction and OFF no shading cor...

Страница 14: ...wever total with ROIHS cannot exceed 720 720 Synchro scan When ROIVW 540 1H 586H to 571H 586H OFF 2FRM to 120FRM OFF When ROIVW 540 1H ROIVW 42 H to ROIVW 27 H ROIVW 42 H OFF 2FRM to 120FRM OFF Trigger 1P SR POSI NEGA POSI Trigger PW SR POSI NEGA POSI 1P exposure time 0 03ms 16ms 16 ms AUTO Level 100 0 100 0 AUTO Peak Average 00 10 05 05 10 00 05 05 Gain MODE MANU OFF OFF MANU 0dB 18dB 0dB White b...

Страница 15: ...while the Index menu is displayed AUTO NR MANU PED E TRG RR E TRG 1P SR E TRG PW SR SS MANU AWB WHT BAL ON MANU OFF GAMMA GAMMA OFF MANU PAGE PAGE PAGE PAGE PAGE EXT OUTPUT INT BAUD RATE SHUTTER GAIN PROCESS SYNC SHADING OPTION PAGE PAGE C SHAD OFF V SHAD MANU V SHAD OFF C SHAD MANU POWER ON DISP PAGE PAGE DISP DISP Video signal output Index menu Menues 7 2 Menus Select the menu to change the sett...

Страница 16: ...r E TRG includes the three modes described below For details of specifications refer to the item 7 4 E TRG External trigger 1P SR 1 Pulse Sync Reset The charge begins to accumulate to each CMOS pixels after the trigger pulse is received Upon completion of accumulation the vertical sync signal is reset and 1 frame images are output The exposure accumulation time can be set from 0 03 to 16 ms The tr...

Страница 17: ...T 36000 1 36000s NORMAL 39000 1 39000s FAST When doing partial scanning you cannot set a shutter speed that is slower than one vertical scan interval determined by the set vertical scan width ROIVW a Changing the shutter speed Move the to MANU by pushing MENU UP MENU DOWN buttons Select the shutter speed by pushing DATA UP DATA DOWN buttons b To change the settings for partial scanning Move the to...

Страница 18: ...Changing the shutter speed setting Move the to SS by pushing MENU UP MENU DOWN buttons Select the shutter speed by pushing DATA UP DATA DOWN buttons b To change the settings for partial scanning Move the to PART by pushing the MENU UP and MENU DOWN buttons Select the mode you want by pushing the DATA UP and DATA DOWN buttons When ON or EXT is set Move the to the setting item you want by pushing th...

Страница 19: ...scanning is off ON Partial scanning is on You can set the area for partial scanning See 7 5 Partial Scanning EXT You can switch between ON and OFF by using external controls a Changing the polarity of the input trigger pulse setting Move the to TRG P by pushing MENU UP MENU DOWN buttons Select either POSI NEGA by pushing DATA UP DATA DOWN buttons b Changing 1P SR exposure time setting Move the to ...

Страница 20: ...sing external controls a Changing the polarity of the input trigger pulse setting Move the to TRG P by pushing MENU UP MENU DOWN buttons Select either POSI NEGA by pushing DATA UP DATA DOWN buttons b To change the settings for partial scanning Move the to PART by pushing the MENU UP and MENU DOWN buttons Select the mode you want by pushing the DATA UP and DATA DOWN buttons When ON or EXT is set Mo...

Страница 21: ...U DOWN buttons Select the setting values you want by pushing the DATA UP and DATA DOWN buttons If PART is set to OFF the setting values for partial scanning are not shown Note The longer the storage time with extended exposures the more visible certain characteristics of CMOS cameras become fixed pattern noise white pixels etc 1 4 Changing each setting in AUTO mode Peak Average ratio adjustment 00...

Страница 22: ... steps OFF Gain is fixed at 0dB Move the to MODE push the DATA UP DATA DOWN and select one of the two modes between MANU and OFF 2 1 Changing the setting in GAIN MODE MANU MANU 0dB GAIN Gain mode MANU OFF Manual gain adjustment 0 dB to 18 dB 1 dB step Move up down by pushing MENU UP DOWN Select the desired value by pushing DATA UP DOWN a Changing the gain in MANU mode Move the to MANU by pushing M...

Страница 23: ...Changing color temperature setting Move the to C TEMP by pushing MENU UP MENU DOWN buttons Select either 3200 5600P or 5600C by pushing DATA UP DATA DOWN buttons 3 2 Changing the setting in MANU Manual mode MODE MANU R GAIN 0 0 B GAIN C TEMP 3200 WHT BAL Red gain adjustment 100 to 100 White balance mode AWB MANU Color temperature setting 3200 5600P 5600C Blue gain adjustment 100 to 100 Move up dow...

Страница 24: ...desired value by pushing DATA UP DOWN 4 1 Changing gamma correction Move the to GAMMA by pushing MENU UP MENU DOWN buttons Select the gamma correction by pushing DATA UP DATA DOWN buttons 4 2 Changing master pedestal Move the to M PED by pushing MENU UP MENU DOWN buttons Adjust the master pedestal by pushing DATA UP DATA DOWN buttons 4 3 Changing R pedestal Move the to R PED by pushing MENU UP MEN...

Страница 25: ... the red correction area on left and right side B size B SIZE 0 63 small large Adjust the blue correction area of the corner B gain B GAIN 32 0 31 low high Adjust the blue correction level B position B POSI 32 0 31 Left area compression Right area compression Adjust the blue correction area on left and right side OFF The status is no shading correction The shading correction is effective when the ...

Страница 26: ...U is not displayed in the menu 5 4 Changing the manual C SHAD Corner Shading correction setting a Changing the red size setting Move the to R SIZE by pushing MENU UP MENU DOWN buttons Adjust the R size by pushing DATA UP DATA DOWN buttons b Changing the red gain setting Move the to R GAIN by pushing MENU UP MENU DOWN buttons Adjust the R gain by pushing DATA UP DATA DOWN buttons c Changing red pos...

Страница 27: ...DATA DOWN buttons 7 OPTION Serial baud rate setting 9600 19200 Frame rate setting NORMAL FAST Communication speed setting Set the speed to the baud rate setting on the personal computer side BAUD RATE OUTPUT NORMAL 9600 OPTION Move up down by pushing MENU UP DOWN Select the desired value by pushing DATA UP DOWN 7 1 Changing serial communication baud rate Move the to BAUD RATE by pushing MENU UP ME...

Страница 28: ... speed can be set by the horizontal scanning period 1H or by the number of frames 1 Setting by 1H You can set the shutter speed in increments of 1H NORMAL 13 74 μs FAST 11 31 μs You can set the following values Partial Scanning OFF 1H 586H to 571H 586H Partial Scanning ON 1H ROIVW 42 H to ROIVW 27 H ROIVW 42 H ROIVW is the value set for vertical width in partial scanning 2 Setting by the frame 2FR...

Страница 29: ...H 2 Approx 2H Exposure period 3 Exposure completion Approx 26H Internal VD 4 RGB data video interval image FVAL LVAL DVAL 5 13H Partial scanning OFF 11H Partial scanning ON Trigger signal to internal signal sensor 1 External input signal 2 Frame rate NORMAL mode 1H 13 74 μs FAST mode 1H 11 31 μs 3 Exposure time is determined by the EXP setting on the menu See page 16 4 VD is generated after about ...

Страница 30: ...itive polarity mode 13H Partial scanning OFF 11H Partial scanning ON 1 External input signal 2 Frame rate NORMAL mode 1H 13 74 μs FAST mode 1H 11 31 μs 3 Exposure period Pulse width of trigger signal to sensor in 1H units 14 26 μs Pulse width of trigger signal tw is rounded to 1H units as shown below n 1 tw n n whole number greater than 1 4 VD is generated after about 26H following the completion ...

Страница 31: ...is please input from an external source a VD signal that has an expanded VD pulse and VD pulse interval Reset Restart Picture Output Timing Exposure period 2 Exposure period Exposure period 3 Approx 18H V reset Approx 1H 1 V reset Approx 1H 1 Approx 31H External HD IN External VD IN Internal VD FVAL LVAL DVAL VD signal to internal signal sensor 13H Partial scanning OFF 11H Partial scanning ON RGB ...

Страница 32: ... can set the specified area by using 4 parameters Video interval image NORMAL ROIVW 42H 72 794 kHz 1000 s FAST ROIVW 42H 88 393 kHz 1000 s ROIVW The value set for vertical width in partial scanning Vertical width ROIVW Vertical start position ROIVS Horizontal width ROIHW Horizontal start position ROIHS Video Timing Internal VD FVAL One vertical scan interval A LVAL DVAL RGB data video interval ima...

Страница 33: ...xternal Video is output due to VD input N Y HD is synchronized to the inside of the camera Video is output due to VD input N Video is not output because there is no VD input Normally not used At time of manual shutter N N Internal sync mode Y Y External sync mode Y N HD is synchronized to external Normally not used N Y Disabled Either Y or N is permitted 1 External sync signal polarity HD Negative...

Страница 34: ...standard center phase Note that V sync of the video is output with a delay of about 2H from the external VD at the time of reset restart and the external trigger mode Other than for reset restart or external trigger mode Continuously with the HD cycle NORMAL 13 74 μs FAST 11 31 μs Continuously with the VD cycle NORMAL 8 05 ms FAST 6 63 ms partial scanning is NORMAL 72 794 kHz 1000 ROIVW 42H FAST 8...

Страница 35: ... Horizontal blanking interval NORMAL 96 clk FAST 120 clk NORMAL 1 62μs FAST 1 62μs Output video interval 720 clk NORMAL 12 12μs FAST 9 70μs clk NORMAL 16 84ns FAST 13 47ns NORMAL 59 4MHz FAST 74 25MHz Vertical Output Waveform Timing Chart FVAL RGB data NORMAL 8 05ms FAST 6 63ms Vertical blanking interval 46H NORMAL 0 63ms FAST 0 52ms Output video interval 540H NORMAL 7 42ms FAST 6 11ms One vertica...

Страница 36: ...Is the shutter mode set correctly Is the monitor on and in working condition Is the image signal output mode set correctly Is the image process equipment set correctly Poor color Is the monitor adjusted correctly Is the white balance of the camera adjusted correctly Is the illumination sufficient Noise appears Is the camera cable connected securely Are the camera and video cables connected correct...

Страница 37: ... mount Ambient temperature 0 C to 40 C 32 to 104 F Ambient humidity 90 or less no condensation Weight Approx 160 g 0 353 lbs External dimension except for protruded portion 44 W x 44 H x 78 D mm 1 73 W x 1 73 H x 3 07 D White balance AWB Automatic white balance MANUAL Manual Gain MANUAL Manual OFF 0 dB Partial scanning ON OFF EXT external control Frame rate conversion NORMAL FAST Output signal 8 b...

Страница 38: ...EARANCE DIAGRAM Unit mm inch inch mm 25 4 44 1 73 34 1 34 44 1 73 22 0 87 26 1 02 5 0 20 2 M3 Depth 3 78 3 07 6 3 0 25 5 0 20 56 2 20 4 M3 Depth 3 26 1 02 25 0 98 4 M2 Depth 3 8 2 0 32 19 2 0 76 12 0 47 2 M2 25 0 98 26 1 02 25 0 98 ...

Страница 39: ...2B996 016JA 39 ...

Страница 40: ...1385 Shimoishigami Otawara shi Tochigi 324 8550 Japan CANON MEDICAL SYSTEMS CORPORATION 2018 ALL RIGHTS RESERVED ...

Отзывы: