Chapter 7
7-7
F-7-11
7.4.6 APC Correction
0015-4484
iR5065 / iR 5055 / iR5075 / iR5075N / iR5065N / iR5055N
Changes in the laser output cause changes in the surface potential. To maintain a specific level of surface potential, the machine corrects the laser output control
value. The following shows the type and the particulars of laser output control value correction:
F-7-12
(1) Between-Sheet APC Control
Purpose: to maintain a specific level of surface potential without lowering the productivity during a continuous job; the machine measures the potential after
laser output between sheets, and corrects the laser output control value.
Timing: over the 1st interval between sheets every 1 min after the start of a continuous print job.
Potential measurement: the drum potential varies in drum peripheral direction; thus, the machine computes the average drum surface potential in drum
peripheral direction. It uses the result of computation to determine the laser output correction value. If measurement is not possible because of conditions
imposed by the need for measurement between sheets, the machine will continue measurement for an additional 1 min.
(2) Initial Rotation APC Control
Purpose: to make up for the changes in the VL potential of the laser output occurring after an appreciable time, the machine measures the drum potential and
corrects the laser output control value.
Timing: during initial rotation of the 1st job 60 min after the end of a job.
Potential measurement: the drum potential varies in peripheral direction, and the machine computes the average drum potential in peripheral direction. The
machine uses the result of computation to obtain the appropriate laser output correction value.
(3) Last Rotation APC Control
Purpose: when intermittent printing is repeated at short intervals, the absence of potential control can cause changes in the VL potential of the laser output.
To make up for the changes, the machine computes a correction value for the laser output control value and uses the result for the next job.
Timing: during last rotation for the 1st job 30 min after the most recent laser output correction.
Potential measurement: the drum potential varies in peripheral direction. The machine computes the average drum potential in peripheral direction, and
obtains the appropriate laser output correction value using the result of computation.
SERVICE MODE:
COPIER>OPTION>BODY>LAPS-SW (switching laser correction)
0: ON (left alone for 10 min -> initial rotation APC)
1: ON (left alone for 60 min -> initial rotation APC; default)
2: ON (left alone for 120 min -> initial rotation APC)
3: OFF only for initial rotation APC
4: OFF
7.4.7 Adjusting the Density in Various Modes
0015-4486
iR5065 / iR 5055 / iR5075 / iR5075N / iR5065N / iR5055N
The machine corrects the development bias determined as a result of potential control for the following operating modes, and uses the result as the target value for
the individual modes:
WMUPR
WMUP
STBY
200 C
Potential sensor
Resulting
potential
Laser
Secondary
charging
VpcVpc
LP0
Vpc
Potential control sequence start
VD
VL1
VL2
Vdc
VD
Vdc
Photosensitive
drum
Developing
cylinder
Potential sensor
Laser output
determined
Fixing assembly temperature 195 C
LP
Primary charging
current determined
Copier
potential
control
Printer
potential
control
Main power
switch ON
Fixing assembly temperature 195- C
(fixing assembly warm-up complete)
Control panel power switch ON
Start key ON
laser output
value correction
1 min later
1 min later
Continuous printing
Laser output
value correction
Содержание iR5055
Страница 1: ...Feb 29 2008 Service Manual iR5075 5065 5055 Series ...
Страница 2: ......
Страница 6: ......
Страница 27: ...Contents 19 1 2 List of Solvents Oils 19 2 ...
Страница 28: ...Contents ...
Страница 29: ...Chapter 1 Introduction ...
Страница 30: ......
Страница 32: ......
Страница 59: ...Chapter 2 Installation ...
Страница 60: ......
Страница 104: ...Chapter 2 2 42 F 2 156 2 1 ...
Страница 105: ...Chapter 3 Basic Operation ...
Страница 106: ......
Страница 108: ......
Страница 115: ...Chapter 4 Main Controller ...
Страница 116: ......
Страница 118: ......
Страница 135: ...Chapter 5 Original Exposure System ...
Страница 136: ......
Страница 169: ...Chapter 6 Laser Exposure ...
Страница 170: ......
Страница 172: ......
Страница 178: ......
Страница 179: ...Chapter 7 Image Formation ...
Страница 180: ......
Страница 184: ......
Страница 217: ...Chapter 8 Pickup Feeding System ...
Страница 218: ......
Страница 274: ......
Страница 275: ...Chapter 9 Fixing System ...
Страница 276: ......
Страница 280: ......
Страница 320: ......
Страница 321: ...Chapter 10 External and Controls ...
Страница 322: ......
Страница 326: ......
Страница 336: ...Chapter 10 10 10 F 10 7 2 Remove the check mark from SNMP Status Enabled ...
Страница 337: ...Chapter 10 10 11 F 10 8 ...
Страница 361: ...Chapter 11 MEAP ...
Страница 362: ......
Страница 364: ......
Страница 409: ...Chapter 12 e maintenance imageWARE Remote ...
Страница 410: ......
Страница 412: ......
Страница 421: ...Chapter 13 Maintenance and Inspection ...
Страница 422: ......
Страница 424: ......
Страница 433: ...Chapter 14 Standards and Adjustments ...
Страница 434: ......
Страница 464: ......
Страница 465: ...Chapter 15 Correcting Faulty Images ...
Страница 466: ......
Страница 468: ......
Страница 496: ......
Страница 497: ...Chapter 16 Self Diagnosis ...
Страница 498: ......
Страница 500: ......
Страница 528: ......
Страница 529: ...Chapter 17 Service Mode ...
Страница 530: ......
Страница 532: ......
Страница 600: ......
Страница 601: ...Chapter 18 Upgrading ...
Страница 602: ......
Страница 604: ......
Страница 636: ...Chapter 18 18 32 F 18 59 2 Select the data to download F 18 60 3 Click Start ...
Страница 638: ......
Страница 639: ...Chapter 19 Service Tools ...
Страница 640: ......
Страница 641: ...Contents Contents 19 1 Service Tools 19 1 19 1 1 List of Special Tools 19 1 19 1 2 List of Solvents Oils 19 2 ...
Страница 642: ......
Страница 645: ...Feb 29 2008 ...
Страница 646: ......