Adjustment when Replacing the Parts
Handling Finisher Controller PCB Replacements
■ Handling before replacement
• When backup is possible
1. Before replacing the finisher controller PCB, store the adjustment values and the counter of the consumable parts to
the host machine from the service mode of the host machine.
(Lv.1) SORTER > FUNCTION > FIN-BK-R
2. Turn OFF/ON the main power switch.
• If the host machine was not able to store the adjustment values
1. Before replacing the finisher controller PCB, output the service mode setting values by P-PRINT.
(Lv.1) COPIER > FUNCTION > MISC-P > P-PRINT
If P-PRINT cannot be output, handling before replacement is not performed.
■ Preparation/Procedure
“Removing the Finisher Controller PCB” on page 67
■ Handling after replacement
NOTE:
If the finisher version is old, a message prompting you to update will appear.If this message appears, update it automatically.
If you select to skip the message screen indicating that the combination is not correct, the message will appear every time you
start the host machine unless you disable the message in service mode.
<Related Service Mode>
(Lv.2) COPIER > OPTION > FNC-SW > VER-CHNG
Setting of firmware update operation
• If backup operation has been performed
1. Write the adjustment values and the counter of the consumable parts to the new PCB from the service mode of the host
machine.
(Lv.1) SORTER > FUNCTION > FIN-BK-W
2. Turn OFF/ON the main power switch.
5. Adjustment
75
Содержание Inner Finisher-J1
Страница 10: ...Product Overview 1 Features 5 Specifications 6 Name of Parts 9 ...
Страница 45: ...Periodical Service 3 List of Work for Scheduled Servicing 40 ...
Страница 78: ...Adjustment 5 Overview 73 Adjustment when Replacing the Parts 75 Service Label 77 ...
Страница 88: ...Installation Outline Drawing 1 2 3 4 5 8 9 10 11 6 7 12 6 Installation 82 ...
Страница 99: ...APPENDICES Service Tools 94 General Circuit Diagram 95 ...