3. Toner Bottle Counters
The imageRUNNER ADVANCE DX 4700 Series machines also have a
Toner Bottle Counter that counts up after the machines recognize that a
new toner bottle has been inserted. The toner bottle is installed to provide
support for billing customers who order and consume a lot of toner. Toner
units that are shipped can be compared against toner bottles actually
installed in the machine.
Table 31 – Toner Bottle Counters
Toner Bottle Counter
Counter Number
Black:
071
Description
Counts how many toner bottles are consumed throughout
the life of the machine.
Service Mode
COPIER > OPTION > USER > TNRB-SW (Level 2)
Display on the Counter Check
Screen
0: Not displayed
1: Replaced New Toner Bottle Counter (70s) is displayed
2: Not used
3: Replaced New counter & Unidentified counter
(70s, 180s)
4: Premature Replacement counter, Replaced New
counter, & Unidentified counter (60s, 70s, 180s)
Remarks
Backed up three times
49 The counter is not advanced under these conditions after replacing the DC Controller PCB:
- The DC Controller was replaced when the power was OFF, and a new toner bottle was installed before the
power was turned ON.
- The DC Controller was replaced when the power was OFF, the power was turned back ON, and then a new
toner bottle was installed (old bottle was already removed or the front door was open).