Chapter 7
7-5
F-7-7
b. Standard Mode
The machine executes both copier potential control and printer potential control in succession.
F-7-8
In addition to standard mode and short mode, the machine also offers 30-sec mode executed for 30-sec start-up.
c. 30-sec Mode
The machine executes 30-sec mode in a power save state and when it is turned on for the first time for the day.
The machine uses the value of the previous control session to initiate laser exposure, measuring the post-laser illumination potential (VLM) and determining the
developing bias DC (Vdc).
SERVICE MODE:
COPIER> OPTION> BODY> PO-CNT (turning off the potential control mechanism)
0: disable potential control
1: enable potential control (default)
COPIER> OPTION> BODY> PO-CNTMD (selecting potential control mode)
0: 10 min, 60 min potential control OFF (default)
1: 10 min, 60 min short mode
2: 10 min, 60 min normal mode
COPIER> OPTION> TEMPO> F-POT-SW
Enter '1' if a transfer separation fault occurs because of a fault in the potential sensor (as a tentative remedy until the replacement of the sensor).
COPIER> OPTION> TEMPO> F-POT-D
Enabled when '1' is set for the following: COPIER>OPTION>TEMPO>F-POT-SW.
0: if user primarily uses originals with low image ratio (text original; default)
1: if user primarily uses originals with high image ratio (photo original)
2: if re-transfer (drop-out at 50 mm of leading edge) occurs
COPIER> OPTION> TEMPO> F-HUM-SW
Enter '1' if the environment sensor is faulty (as a tentative remedy until replacement of the sensor).
COPIER> OPTION> TEMPO> F-HUM-D
Enabled if '1' is set for the following: COPIER>OPTION>TEMPO-F-HUM-SW.
Enter the humidity reading of the site of installation (between 30% and 99%; default being 35%).
COPIER> FUNCTION> DPC> DPC
(forcing potential control)
ON: execute potential control
COPIER> ADJUST> V-CONT> EPOTOFST
(setting potential sensor offset value)
COPIER> ADJUST> V-CONT> DE-OFST
(adjusting copy Vdc)
COPIER> ADJUST> V-CONT> VD-OFST
(setting copy VD target potential offset value)
COPIER> ADJUST> V-CONT> DE-OFS-P
(adjusting printer Vdc)
COPIER> ADJUST> V-CONT> VD-OFS-P
(setting printer VD target potential offset value)
Enter the value indicated on the service label if you have initialized the RAM on the DC controller PCB.
COPIER> FUNCTION> DPC>OFST
(adjusting potential sensor offset)
For the method of adjustment, see "Standards and Adjustments."
7.4.3 Determining the Primary Current
0015-4481
iR5065 / iR 5055 / iR5075 / / /
To measure the dark area potential (VD) for the first time after the power switch is turned on, the machine uses the most recently measured current level, and meas-
ures the drum surface potential using the potential sensor. The DC controller PCB compares the drum surface potential and the target potential; as a result, if the
measured potential is +/-6 V of the target value, the machine corrects the primary current and measures the potential once again. The machine executes potential
measurement a maximum of 8 times, and also corrects the primary current as many times.
Sets a constant level for both copier
and printer potential control
Copier
potential
control
Printer
potential
control
Fixing assembly temperature
(fixing assembly warm-up complete)
Control panel power switch ON
Start key ON
Potential control
Potential control
Start key ON
10 min later to less
than 60 min
60 min later
Assumes a potential l
evel for the other
based on the result
of copier or printer
potential control
Assumes a potential
level for the other
based on the result
of copier or printer
potential control
Copier
potential
control
Printer
potential
control
Fixing assembly temperature
(fixing assembly warm-up complete)
Control panel power switch ON
Start key ON
Potential control
Potential control
Start key ON
10 min later to less
than 60 min
60 min later
Copier potential control
and printer potential
control during 1st job
Copier potential control
and printer potential
control during 1st job
Содержание imageRUNNER 5055 series
Страница 1: ...Feb 26 2007 Service Manual iR5075 5065 5055 Series ...
Страница 2: ......
Страница 6: ......
Страница 27: ...Chapter 1 Introduction ...
Страница 28: ......
Страница 30: ......
Страница 52: ......
Страница 53: ...Chapter 2 Installation ...
Страница 54: ......
Страница 98: ...Chapter 2 2 42 ...
Страница 99: ...Chapter 3 Basic Operation ...
Страница 100: ......
Страница 102: ......
Страница 108: ......
Страница 109: ...Chapter 4 Main Controller ...
Страница 110: ......
Страница 112: ......
Страница 129: ...Chapter 5 Original Exposure System ...
Страница 130: ......
Страница 162: ......
Страница 163: ...Chapter 6 Laser Exposure ...
Страница 164: ......
Страница 166: ......
Страница 172: ......
Страница 173: ...Chapter 7 Image Formation ...
Страница 174: ......
Страница 178: ......
Страница 210: ......
Страница 211: ...Chapter 8 Pickup Feeding System ...
Страница 212: ......
Страница 263: ...Chapter 9 Fixing System ...
Страница 264: ......
Страница 268: ......
Страница 307: ...Chapter 10 External and Controls ...
Страница 308: ......
Страница 312: ......
Страница 321: ...Chapter 10 10 9 F 10 8 ...
Страница 345: ...Chapter 11 MEAP ...
Страница 346: ......
Страница 348: ......
Страница 389: ...Chapter 12 RDS ...
Страница 390: ......
Страница 392: ......
Страница 399: ...Chapter 13 Maintenance and Inspection ...
Страница 400: ......
Страница 402: ......
Страница 411: ...Chapter 14 Standards and Adjustments ...
Страница 412: ......
Страница 440: ......
Страница 441: ...Chapter 15 Correcting Faulty Images ...
Страница 442: ......
Страница 444: ......
Страница 470: ......
Страница 471: ...Chapter 16 Self Diagnosis ...
Страница 472: ......
Страница 474: ......
Страница 493: ...Chapter 17 Service Mode ...
Страница 494: ......
Страница 496: ......
Страница 552: ......
Страница 553: ...Chapter 18 Upgrading ...
Страница 554: ......
Страница 556: ......
Страница 572: ...Chapter 18 18 16 F 18 29 2 Click Start F 18 30 3 When the session has ended click OK ...
Страница 587: ...Chapter 18 18 31 F 18 59 2 Select the data to download F 18 60 3 Click Start ...
Страница 589: ...Chapter 19 Service Tools ...
Страница 590: ......
Страница 591: ...Contents Contents 19 1 Service Tools 19 1 19 1 1 List of Special Tools 19 1 19 1 2 List of Solvents Oils 19 1 ...
Страница 592: ......
Страница 595: ...Feb 26 2007 ...
Страница 596: ......