Chapter 3
3-106
6) While holding the left and right frames [2] of the
Fixing film unit [1], lift it up at an angle and remove
it.
F-3-459
3.6.2.18
Removing the Fixing
Pressure Roller
0006-3726
1) Remove the gear [1] by disengaging the claw.
2) Take out the boss of the bushing [2], turn it, and
remove the bushing.
F-3-460
3) Hold the shorter shaft [2] of the Fixing pressure
roller [1] and lift it up at an angle to remove it from
the bushing. Remove the Fixing pressure roller by
sliding it.
F-3-461
[1]
[2]
[1]
[2]
[2]
[1]