5-11
CHAPTER 5 SELF DIAGNOSIS
C. Cassette Feeding Unit-R1/S1
Code
E901
E716
Cause
The pedestal has an error.
•
The pedestal controller PBC has an
error.
•
The connector has poor connection.
•
The 24-V power supply has a fault.
•
The pedestal motor (M20) has a fault.
•
The pedestal controller PCB has a
fault.
Description
The communication IC (Q101)
on the pedestal controller PCB
is out of order.
•
The pedestal motor does not
rotate at a specific speed
within 10 sec after it has
turned on.
•
The pedestal motor speed
deviates
D. Multi Output Tray-D1
Code
E540
Cause
The shift tray home position sensor fails.
Description
The home position detection
signal does not turn on within 5
sec when making a shift tray
home position search.