background image

95

7

5

 Remove the feed rollers.

6

 Place the new feed rollers on the pin.

7

 Set the feed rollers in place (

q

), and align the notch in the roller’s

axle with the shaft on the scanner (

w

).

7.2   Replacing the Rollers

Содержание DR-6080

Страница 1: ...ENGLISH CANON DOCUMENT SCANNER Maintenance Guide Please read this manual before operating this unit After you finish reading this manual store it in a safe place for future reference...

Страница 2: ...Detection Sensor 81 Cleaning the Scanning Glasses and Rollers 81 Cleaning the Shading Plates 85 Cleaning the Guide Plate When Using the Imprinter 87 Cleaning the Ink Jet Nozzles When Using the Imprin...

Страница 3: ...scanner with any kind of organic solvent such as alcohol benzene or paint thinner It might cause a fire and electrical shock or cause the exterior of the scanner to disfigure of discolor Never spray...

Страница 4: ...s appearing on scanned images or dirt appearing on scanned documents is dirt on the scanning glasses or rollers Clean the scanning glasses and rollers regularly 1 Press the power switch to turn OFF th...

Страница 5: ...ning glasses Be sure to clean both scanning glasses the one below and one above Never spray mild detergent or water directly on the scanning glasses The spray could penetrate below the glass and conta...

Страница 6: ...indicated in the figure below Feeding Rollers Pickup Rollers Retard Rollers Feed Rollers Platen Rollers 6 Remove the pickup roller retard roller and feed roller See Installing and Removing the Rollers...

Страница 7: ...es to close it If you press the upper scanner down only on one side the opposite side will not be fully closed Make sure that you hear it click into place If paper jams or double feed feeding of two o...

Страница 8: ...nner is ON when you are cleaning the shading plates so be very careful 1 Open the upper scanner Press the open close button and lift up the upper scanner gently until it stops and locks in the open po...

Страница 9: ...r scanner down firmly on both sides to close it If you press the upper scanner down only on one side the opposite side will not be fully closed Make sure that you hear it click into place If there is...

Страница 10: ...Jet Nozzles When Using the Imprinter Ink that collects around the ink jet nozzle may stain your documents or cause the text to appear scratchy Remove the ink jets and clean them periodically with cott...

Страница 11: ...er In this case buy the exchange roller kit and replace the feed rollers pickup rollers feed rollers and retard rollers Be sure to reset the counter after changing the counter Windows NT do not suppor...

Страница 12: ...d rollers 1Click the Start button and then click Settings Control Panel 2 Double click on the Scanners and Cameras icon Windows NT do not display the Scanners and Cameras icon The displayed dialog box...

Страница 13: ...90 Chapter 7 Daily Cleaning 3 Select the scanner that you are using and click on the Properties button 4 Click the Counter tab 5 Click the Reset button and confirm whether the counter is reset to 0...

Страница 14: ...OFF the power to the scanner and unplug the power cord from the power outlet when you remove or install the rollers Leaving the power turned ON may result in an electrical shock When removing or repla...

Страница 15: ...talling and Removing Pickup Rollers 1 Open the upper scanner 2 Open the roller cover 3Open the roller holder and remove the pickup rollers 4Position the square axle of the pickup roller on the left an...

Страница 16: ...the roller cover until you hear it click 7Carefully close the upper scanner If the roller holder and roller cover are not firmly closed it will cause a feed error Always be sure to check that the rol...

Страница 17: ...ning Installing and Removing Feed Rollers 1Open the upper scanner 2Open the roller cover 3 Pull the lever that locks the feed rollers in place towards you 4 Slide the feed rollers to the right and the...

Страница 18: ...95 7 5Remove the feed rollers 6Place the new feed rollers on the pin 7Set the feed rollers in place q and align the notch in the roller s axle with the shaft on the scanner w 7 2 Replacing the Rollers...

Страница 19: ...the lever 9Firmly close the roller cover until you hear it click 10Carefully close the upper scanner If the roller cover is not firmly closed it will cause a feed error Always be sure to check that th...

Страница 20: ...97 7 Installing and Removing Retard Rollers 1Open the upper scanner 2Remove the roller cover 3Lift the roller clamp lever q and slide it to the left w 7 2 Replacing the Rollers...

Страница 21: ...tard rollers to the left and remove them 5Set the new retard rollers in place and align the notch in the roller s axle with the shaft on the scanner 6Slide the roller clamp lever to the right and push...

Страница 22: ...he roller cover is not loose If the roller cover is loose the document tray will catch on it causing the scanner to not operate correctly Never clean the scanner with any kind of organic solvent such...